GB/T 25105.2-2014
Industrial communication networks.Fieldbus specifications.Type 10 PROFINET IO specifications.Part 2:Application layer protocol specification (English Version)

Standard No.
GB/T 25105.2-2014
Language
Chinese, Available in English version
Release Date
2014
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 25105.2-2014
Replace
GB/Z 25105.2-2010
Scope
Overview The Fieldbus Application Layer (FAL) provides user programs with the means to access the fieldbus communication environment. In this respect, the Fieldbus Application Layer (FAL) can be considered as a "window between the corresponding applications". GB/T 25105 provides general elements and PROFINET IO field bus-specific information for basic time-critical and non-time-strict message communication between applications in an automation environment. The term "strictly timed" is used to indicate that there is a time window within which one or more specified actions are required to be completed with a definite degree of certainty. Failure to complete the specified actions within this time window will result in the risk of failure of the application requesting these actions, and even cause equipment, equipment and possible personal danger. This part of GB/T 25105 defines the externally visible behavior provided by the fieldbus application layer in an abstract way from the following aspects: a) defines the abstract syntax of the application layer protocol data unit transmitted between communication application entities; b) Define the transfer syntax of the application layer protocol data unit transmitted between the communication application entities; c) define the application context state machine of the application service behavior visible between the communication application entities; d) define the communication application entity An application relational state machine for the communication behavior of a view. The purpose of this section is to define a protocol for the following purposes: a) defining the byte transfer order of service primitives defined in PROFINET IO service files; b) defining externally visible behavior related to their transfer. This part specifies the PROFINET IO field bus application layer protocol based on the OSI basic reference model (see GB/T 9387) and the OSI application layer structure (GB/T 17176). The primary goal of this part of the specification is to fix the syntax and behavior of the application-layer protocol that conveys the application-layer services defined in PROFINET IO. The second goal is to provide an upgrade path to existing industrial communication protocols. It was this goal that resulted in the IEC 6115

GB/T 25105.2-2014 Referenced Document

  • GB/T 15695 Information technology.Open Systems Interconnection.Presentation service definition
  • GB/T 16262.1 Information technology - Abstract syntax notation one (ASN.1) - Part 1: Specification of basic notation
  • GB/T 17176 Information technology--Open Systems Interconnection--Application layer structure
  • GB/T 17966 Binary floating-point arithmetic for microprocessor systmes
  • GB/T 17967 Information technology-Open Systems Interconnection-Basic reference model-Convention for the definition of OSI services
  • GB/T 1988 Information technology--7-bit Coded character set for information interchange
  • GB/T 20540.1 Digital data communication for measurement and control Fieldbus for use in industrial control systems Type 3: PROFIBUS specification Part 1: Overview and guidance
  • GB/T 20540.2 Digital data communication for measurement and control Fieldbus for use in industrial control systems Type 3: PROFIBUS specification Part 2: Physical layer specification and service definition
  • GB/T 20540.3 Digital data communication for measurement and control Fieldbus for use in industrial control systems Type 3: PROFIBUS specification Part 3: Data link layer service definiton
  • GB/T 20540.4 Digital data communication for measurement and control Fieldbus for use in industrial control systems Type 3: PROFIBUS specification Part 4: Data link layer protocol specification
  • GB/T 20540.5 Digital data communication for measurement and control Fieldbus for use in industrial control systems Type 3: PROFIBUS specification Part 5: Application layer service definition
  • GB/T 20540.6 Digital data communication for measurement and control Fieldbus for use in industrial control systems Type 3: PROFIBUS specification Part 6: Application layer protocol specification
  • GB/T 7408 Data elements and interchange formats-Information interchange-Representation of dates and times
  • GB/T 9387.1 Information technology--Open Systems Interconnection--Basic Reference Model--Part 1: The Basic Model
  • IEC 61158 Corrigendum 1 - Digital data communications for measurement and control - Fieldbus for use in industrial control systems - Part 6: Application layer protocol specification
  • IEC 61784-3-3 Industrial communication networks - Profiles - Part 3-3: Functional safety fieldbuses - Additional specifications for CPF 3*2021-05-01 Update

GB/T 25105.2-2014 history

  • 2014 GB/T 25105.2-2014 Industrial communication networks.Fieldbus specifications.Type 10 PROFINET IO specifications.Part 2:Application layer protocol specification
  • 2010 GB/Z 25105.2-2010 Industrial communication networks.Fieldbus specifications.Type 10:PROFINET IO specifications.Part 2:Application layer protocol specification

GB/T 25105.2-2014 Industrial communication networks.Fieldbus specifications.Type 10 PROFINET IO specifications.Part 2:Application layer protocol specification has been changed from GB/Z 25105.2-2010 Industrial communication networks.Fieldbus specifications.Type 10:PROFINET IO specifications.Part 2:Application layer protocol specification.

Industrial communication networks.Fieldbus specifications.Type 10 PROFINET IO specifications.Part 2:Application layer protocol specification

GB/T 25105.2-2014 -All Parts