GB/T 24338.6-2009
Railway applications.Electromagnetic compatibility.Part 5:Emission an immunity of fixed power supply installations and apparatus (English Version)

Standard No.
GB/T 24338.6-2009
Language
Chinese, Available in English version
Release Date
2009
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2019-01
Replace By
GB/T 24338.6-2018
Latest
GB/T 24338.6-2018
Scope
This part of GB/T 24338 specifies the emission and immunity requirements for electrical and electronic equipment and systems in track ground power supply installations, including the power supply to the equipment, the equipment itself and its protection and control circuits, as well as switching stations, power Wayside equipment such as autotransformers, voltage regulating transformers, power switches of substations, power supply switches of other longitudinal and local power sources, etc. This section does not apply to filters operating on the traction supply voltage (such as for harmonic suppression or power factor compensation), because each site has specific requirements. Filters should usually have separate enclosures and separate proximity rules. If electromagnetic limits are required, they shall be specified in the equipment specification. The limits in this section do not apply to intended communication signals. The frequency coverage range is 0GHz~400GHz. At present, only the electromagnetic compatibility test of 2GHz and below is regulated. The emission and immunity requirements specified in this part are applicable to the equipment in the following places: a) equipment for power supply to the rail transit system in the substation; b) equipment for trackside control and adjustment of the power supply of the rail transit system, including power factor Compensation and filtering equipment; c) The power supply network along the track except for the conductors of the contact system and the return conductors connected to it, including the high-voltage feeder system that supplies power to the substation within the scope of the track, within the scope of the substation, will come from A system that converts the voltage of the high-voltage feeder system into the voltage required by the track system, such as 25-0-25kV, 50Hz system transmission lines and 110kV, 16.7Hz power supply systems. Outside the track range, the transmission wires that are only used for power supply to the track system are also used as General overhead line handling in public areas; d) Power supply equipment for trackside control and regulation auxiliary purposes, including power supplies for railway freight marshalling yards, maintenance stations and stations sd various non-traction power supplies shared with track traction. Equipment and systems located in residential areas, commercial areas or light industrial areas, even within the physical range of traction substations, should also comply with general EMC national standards. The immunity requirements of this part do not apply to power supply equipment that has inherent immunity to the tests defined in Tables 1 to 6 of this part.

GB/T 24338.6-2009 Referenced Document

  • CISPR 16-1 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus
  • GB 17625.1 Electromagnetic compatibility—Limits—Part 1: Limits for harmonic current emissions (equipment input current ≤ 16A per phase)*2022-12-29 Update
  • GB 17799.4 Electromagnetic compatibility (EMC)—Generic standards—Part 4: Emission for industrial environments*2022-10-12 Update
  • GB 9254 Limits and methods of measurement of radio disturbance for information technology equipment
  • GB/T 17625.2 Eiectromagnetic compatibility limits(EMC) - Limitation of voltage changes,voltage fluctuations and flicker in public low-voltage supply systems,for equipment with rated current ≤16A per phase and not subject to conditional connection
  • GB/T 17626.12 Electromagnetic Compatibility Testing and Measurement Techniques Part 12: Ringing Wave Immunity Test*2023-03-17 Update
  • GB/T 17626.16 Electromagnetic compatibility Testing and measurement techniques Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
  • GB/T 17626.2 Electromagnetic compatibility.Testing and measurement techniques.Electrostatic discharge immunity test*2018-06-07 Update
  • GB/T 17626.3-2006 Electromagnetic compatibility Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test
  • GB/T 17626.4 Electromagnetic compatibility-Testing and measurement techniques-Electrical fast transient/burst immunity test*2018-06-07 Update
  • GB/T 17626.5 Electromagnetic compatibility—Testing and measurement techniques-Surge immunity test*2019-06-04 Update
  • GB/T 17626.6 Electromagnetic compatibility—Testing and measurement techniques—Immunity to conducted disturbances,induced by radio-frequency fields*2017-12-29 Update
  • GB/T 17626.8 Electromagnetic compatibility Testing and measurement techniques Power frequency magnetic field immunity test
  • GB/T 17799.2 General Standard for Electromagnetic Compatibility Part 2: Immunity Standards in Industrial Environments*2023-05-23 Update
  • GB/T 24338.1 Railway applications.Electromagnetic compatibility.Part 1:General*2018-06-07 Update
  • IEC 62236-2 Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world*2018-02-09 Update

GB/T 24338.6-2009 history

  • 2018 GB/T 24338.6-2018 Railway applications—Electromagnetic compatibility—Part 5: Emission and immunity of fixed power supply apparatus and systems
  • 2009 GB/T 24338.6-2009 Railway applications.Electromagnetic compatibility.Part 5:Emission an immunity of fixed power supply installations and apparatus

GB/T 24338.6-2009 Railway applications.Electromagnetic compatibility.Part 5:Emission an immunity of fixed power supply installations and apparatus was changed to HB 1-107-1974 Secondary precision (d) small hexagon head bolts for hinge connections.

Railway applications.Electromagnetic compatibility.Part 5:Emission an immunity of fixed power supply installations and apparatus

GB/T 24338.6-2009 -All Parts