This standard applies to the design and manufacture of rolling stock electrical installations and equipment to protect the personnel involved from electric shock. Its requirements vary for different operations and procedures. This standard applies to vehicles in railway transportation systems, road vehicles (trams) powered by external sources, maglev vehicles and equipment on vehicles. This standard does not apply to: mine railways in underground mines; - railway hoists, mobile platforms and similar transport systems; - ropeways; - temporary installations. Test the vehicle according to the requirements of the standard, see IEC 61133.
GB/T 21414-2008 Referenced Document
GB 16895.1 Electrical installations of buildings. Part 1: Scope, object and fundamental principles
GB 16895.11 Electrical installations of buildings Part 4: Protection for safety,Chapter 44: Protection against overvoltages Section 442-Protection of low-voltage installations against temporary overvoltages and faults beween high-voltage systems and earth
GB 16895.12 Electrical installations of buildings Part 4: Protection for safety Chapter 44: Protection against overvoltages Section 443: Protection against overvoltages of atmospheric origin or due to switching
GB 16895.13 Low-voltage electrical installations.Part 7-701:Requirements for special installations or locations.Locations containing a bath or shower*, 2012-06-29 Update
GB 16895.14 Electrical installations of buildings.Part 7-703:Requirements for special installations or locations.Rooms and cabins containing sauna heaters*, 2010-11-10 Update
GB 16895.19 Electrical installations of buildings Part 7: Requirements for special installations or locations Section 702: Swimming pools and other basins
GB 16895.2 Electrical installations of buildings.Part 4-42:Protection for safety.Protection against thermal effects
GB 16895.20 Electrical installations of buildings Part 5: Selection and erection of electrical equipment Chapter 55: Other equipment Section 551: Low-voltage generating sets
GB 16895.21 Low-voltage electrical installations.Part 4-41:Protection for safety.Protection against electric shock*, 2011-12-30 Update
GB 16895.21-2004 Electrical installations of buildings Part 4-41:Protection for safety-Protection against electric shock
GB 16895.22 Electrical installations of buildings Part 5-53:Selection and erection of electrical equipment isolation,switching and control Section 534:Devices for protection against overvoltages
GB 16895.24 Electrical installations of buildings.Part 7-710:Requirements for special installations or locations.Medical locations
GB 16895.25 Electrical installations of buildings.Part 7-711:Requirements for special installations or locations.Exhibitions,shows and stands
GB 16895.26 Electrical installations of buildings.Part 7-740:Requirements for special installations or locations.structures,amusement devices and booths at fairgrounds,amusement parks and circuses
GB 16895.27 Low-voltage electrical installations.Part 7-705:Requirements for special installations or locations.Agricultural and horticultural premises*, 2012-06-29 Update
GB 16895.28 Electrical installations of buildings.Part 7-714:Requirements for special installations or locations.External lighting installations*, 2008-09-19 Update
GB 16895.29 Electrical installations of buildings.Part 7-713:Requirements for special installations or locations.Furniture*, 2008-12-15 Update
GB 16895.3 Electrical installations of buildings--Part 5-54:Selection and erection of electrical equipment-Earthing arrangements,protective conductors and protective bonding conductors
GB 16895.30 Electrical installations of buildings.Part 7-715:Requirements for special installations or locations.Extra-low-voltae lighting installations*, 2008-12-15 Update
GB 16895.31 Electrical installations of buildings.Part 7-717:Requirements for special installations or locations.Mobile or transportable units*, 2008-12-15 Update
GB 16895.4 Electrical installations of buildings Part 4: Protection for safety Chapter 43: Protection against overcurrent
GB 16895.5 Low-voltage electrical installations.Part 4-43 Protection for safety.Protection against overcurrent*, 2012-06-29 Update
GB 16895.6 Electric installations of buildings-Part 5: Selection and erection of electrical equipment-Chapter 52: Wiring systems
GB 16895.7 Low-voltage electrial installatioins.Part 7-704:Requuirements for special installations or locations.Construction and demolition site installations*, 2009-04-21 Update
GB 16895.8 Low-voltage eletrical installations.Part 7-706:Requirements for special installations or locations.Conducting locations with restricted movement*, 2010-11-10 Update
GB 18209.1 Electrical safety of machinery.Indication,marking and actuation.Part 1:Requirements for visual,acoustic and tactile signals*, 2011-01-14 Update
GB 4208 Degrees of protection provided by enclosure(IP code)*, 2008-03-25 Update
GB 7251.12 Low-voltage switchgear and controlgear assemblies.Part 2:Power switchgear and controlgear assemblies*, 2013-12-31 Update
GB 7251.2 Low-voltage switchgear and controlgear assemblies. Part 2: Particular requirements for busbar trunking systems (busways)
GB 7251.3 Low-voltage switchgear and controlgear assemblies. Part 3: Particular requirements for low-voltage switchgear and controlgear assemblies intended to be installed in places where unskilled persons have access for their use. Distribution boards
GB 7251.4 Low-voltage switchgear and controlgear assemblies Part 4: Particular requirements for assemblies for construction sites (ACS)
GB 7251.5 Low-voltage switchgear and control equipment Part 5: Public grid power distribution equipment*, 2017-07-31 Update
GB 7251.6 Low-voltage switchgear and controlgear assemblies.Part 6:Busbar trunking systems (busways)*, 2015-05-15 Update
GB/T 12501 Classification of electrical and electronic equipment with regard to protection against electric shock
GB/T 21413.1-2008 Railway applications.Electric equipment for rolling stock.Part 1:General service conditions and general rules
IEC 60479-1:1994 Effects of Current on Human Beings and Livestock - Part 1: General Aspects (Edition 3.0)
IEC 60850:2000 Railway applications - Supply voltages of traction systems
GB/T 21414-2008 history
2021GB/T 21414-2021 Railway applications—Rolling stock—Protective provisions against electrical hazards
2008GB/T 21414-2008 Railway applications.Rolling stock.Protective provisions against electrical hazards
GB/T 21414-2008 Railway applications.Rolling stock.Protective provisions against electrical hazards has been changed from TB/T 3076-2003 Railway applications-Rolling stock Protective provisions against electrical hazards.