EN 1453-1:2017
Plastics piping systems with structured-wall pipes for soil and waste discharge (low and high temperature) inside buildings - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes and the system

Standard No.
EN 1453-1:2017
Release Date
2017
Published By
European Committee for Standardization (CEN)
Latest
EN 1453-1:2017
Replace
FprEN 1453-1-2016
Scope
This part of EN 1453 specifies the requirements for structured-wall unplasticized poly(vinyl chloride) (PVC-U) pipes and the system intended to be used for soil and waste discharge applications (low and high temperature) inside buildings (application area code "B") NOTE 1 The intended use is reflected in the marking of products by "B". This part of EN 1453 is also applicable to structured-wall unplasticized poly(vinyl chloride) (PVC-U) pipes, and the system intended for the following purposes:- ventilating part of the pipework in association with discharge applications; - rainwater pipework inside building. It also specifies the test parameters for the test methods referred to in this standard. NOTE 2 Single layer foamed PVC-U pipes and spirally-formed PVC-U pipes are not covered by this standard. This standard covers a range of nominal sizes and gives recommendations concerning colours. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. For external above ground application additional requirements depending on the climatic conditions should be agreed between the manufacturer and the user. NOTE 4 Pipes conforming to this standard are normally associated with fittings conforming to EN 1329-1. Pipes, fittings and components conforming to any of the product standards listed in Annex C can also be used with pipes conforming to this standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements in Table 11. NOTE 5 Joints and adhesives are considered to be part of the system as covered in the scope. NOTE 6 Products conforming to this standard may be submitted to national requirements on fire regulation.

EN 1453-1:2017 Referenced Document

  • EN 10204:2004 Metallic products - Types of inspection documents*2024-04-20 Update
  • EN 1329-1:2014 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
  • EN 1401-1:2009 Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
  • EN 1451-1:1998 Plastics Piping Systems for Soil and Waste Discharge (Low and High Temperature) within the Building Structure - Polypropylene (PP) - Part 1: Specifications for Pipes, Fittings and the System
  • EN 1453-1:2000 Plastics Piping Systems with Structured-Wall Pipes for Soil and Waste Discharge (Low and High Temperature) Inside Buildings - Unplasticized Poly(Vinyl Chloride) (PVC-U) - Part 1: Specifications for Pipes and the System
  • EN 1455-1:1999 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Acrylonitrile-butadiene-styrene (ABS) - Part 1: Requirements for pipes@ fittings and the system
  • EN 14680:2015 Adhesives for non-pressure thermoplastics piping systems - Specifications
  • EN 14814:2016 Adhesives for thermoplastic piping systems for fluids under pressure - Specifications
  • EN 1519-1:1999 Plastics Piping Systems for Soil and Waste Discharge (Low and High Temperature) within the Building Structure - Polyethylene (PE) - Part 1: Specifications for Pipes@ Fittings and the System
  • EN 15346:2014 Plastics - Recycled plastics - Characterization of poly(vinyl chloride) (PVC) recyclates
  • EN 1565-1:1998 Plastics Piping Systems for Soil and Waste Discharge (Low and High Temperature) within the Building Structure - Styrene Copolymer Blends (SAN+PVC) - Part 1: Specifications for Pipes@ Fittings and the System
  • EN 1566-1:1998 Plastics Piping Systems for Soil and Waste Discharge (Low and High Temperature) within the Building Structure - Chlorinated Poly(Vinyl Chloride) (PVC-C) - Part 1: Specifications for Pipes@ Fittings and the System
  • EN 1905:1998 Plastics piping systems - Unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and material - Method for assessment of the PVC content based on total chlorine content
  • EN 681-1:1996 Elastomeric Seals - Material Requirements for Pipe Joint Seals Used in Water and Drainage Applications - Part 1: Vulcanized Rubber (Incorporates Amendment A1: 1998)
  • EN 681-2:2000 Elastomeric seals - Materials requirements for pipe joint seals used in water and drainage applications - Part 2: Thermoplastic elastomers
  • EN ISO 1043-1:2011 Plastics - Symbols and abbreviated terms - Part 1: Basic polymers and their special characteristics (ISO 1043-1:2011)*2024-04-20 Update
  • EN ISO 1183-1:2012 Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method (ISO 1183-1:2012)*2024-04-20 Update
  • EN ISO 13229:2011 Thermoplastics piping systems for non-pressure applications - Unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings - Determination of the viscosity number and K-value (ISO 13229:2010)
  • EN ISO 2505:2005 Thermoplastics pipes - Longitudinal reversion - Test method and parameters
  • EN ISO 306:2013 Plastics - Thermoplastic materials - Determination of Vicat softening temperature (VST)*2024-04-20 Update
  • EN ISO 3126:2005 Plastics piping systems - Plastics components - Determination of dimensions ISO 3126:2005
  • EN ISO 3451-5:2002 Plastics - Determination of Ash - Part 5: Poly(Vinyl Chloride) ISO 3451-5: 2002
  • EN ISO 472:2013 Plastics - Vocabulary
  • EN ISO 6259-1:2015 Thermoplastics pipes - Determination of tensile properties - Part 1: General test method
  • EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
  • ISO 11173:1994 Thermoplastics pipes - Determination of resistance to external blows - Staircase method
  • ISO 13254:2010 Thermoplastics piping systems for non-pressure applications - Test method for watertightness
  • ISO 2507-1:1995 Thermoplastics pipes and fittings - Vicat softening temperature - Part 1: General test method
  • ISO 3127:1994 Thermoplastics pipes - Determination of resistance to external blows - Round-the-clock method
  • ISO 6259-2:1997 Thermoplastics pipes - Determination of tensile properties - Part 2: Pipes made of unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly(vinyl chloride) (PVC-C) and high-impact poly(vinyl chloride) (PVC-HI)
  • ISO 9852:2007 Unplasticized poly(vinyl chloride) (PVC-U) pipes - Dichloromethane resistance at specified temperature (DCMT) - Test method

EN 1453-1:2017 history

  • 2017 EN 1453-1:2017 Plastics piping systems with structured-wall pipes for soil and waste discharge (low and high temperature) inside buildings - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes and the system
  • 2000 EN 1453-1:2000 Plastics Piping Systems with Structured-Wall Pipes for Soil and Waste Discharge (Low and High Temperature) Inside Buildings - Unplasticized Poly(Vinyl Chloride) (PVC-U) - Part 1: Specifications for Pipes and the System



Copyright ©2024 All Rights Reserved