EN 1329-1:2014
Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system

Standard No.
EN 1329-1:2014
Release Date
2014
Published By
European Committee for Standardization (CEN)
Status
Replace By
EN 1329-1:2020
Latest
EN 1329-1:2020
Replace
FprEN 1329-1-2013
Scope
This part of EN 1329 specifies the requirements for solid wall unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and the system intended for:- soil and waste discharge applications (low and high temperature) inside buildings (application area code "B"); - soil and waste discharge applications (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code "BD"). NOTE 1 The intended use is reflected in the marking of products by "B" or "BD". NOTE 2 For use buried in ground within the building structure are intended only those components (marked with "BD") with nominal outside diameters equal to or greater than 75 mm. This part of EN 1329 is also applicable to PVC-U pipes, fittings and the system intended for the following purposes; - ventilating part of the pipework in association with discharge applications; - rainwater pipework within the building structure. It also specifies the test parameters for the test method referred to in this European Standard. This European Standard covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. For external above ground application additional requirements depending on the climate should be agreed between the manufacturer and the user. NOTE 4 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this European Standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 24. NOTE 5 Joints and adhesives are considered to be part of the system as covered in the scope.

EN 1329-1:2014 Referenced Document

  • EN 1053:1995 Plastics piping systems - Thermoplastics piping systems for non-pressure applications - Test method for watertightness
  • EN 1054:1995 Plastics piping systems - Thermoplastics piping systems for soil and waste discharge - Test method for airtightness of joints
  • EN 1055:1996 Plastics piping systems - Thermoplastics piping systems for soil and waste discharge inside buildings - Test method for resistance to elevated temperature cycling
  • EN 1277:2003 Plastics piping systems - Thermoplastics piping systems for buried non-pressure applications - Test methods for leaktightness of elastomeric sealing ring type joints*2024-04-20 Update
  • EN 1401-1:2009 Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
  • EN 1411:1996 Plastics piping and ducting systems - Thermoplastics pipes - Determination of resistance to external blows by the staircase method
  • EN 1451-1:1998 Plastics Piping Systems for Soil and Waste Discharge (Low and High Temperature) within the Building Structure - Polypropylene (PP) - Part 1: Specifications for Pipes, Fittings and the System
  • EN 1453-1:2000 Plastics Piping Systems with Structured-Wall Pipes for Soil and Waste Discharge (Low and High Temperature) Inside Buildings - Unplasticized Poly(Vinyl Chloride) (PVC-U) - Part 1: Specifications for Pipes and the System
  • EN 1455-1:1999 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Acrylonitrile-butadiene-styrene (ABS) - Part 1: Requirements for pipes@ fittings and the system
  • EN 1519-1:1999 Plastics Piping Systems for Soil and Waste Discharge (Low and High Temperature) within the Building Structure - Polyethylene (PE) - Part 1: Specifications for Pipes@ Fittings and the System
  • EN 1565-1:1998 Plastics Piping Systems for Soil and Waste Discharge (Low and High Temperature) within the Building Structure - Styrene Copolymer Blends (SAN+PVC) - Part 1: Specifications for Pipes@ Fittings and the System
  • EN 580:2003 Plastics piping systems - Unplasticized poly(vinyl chloride) (PVC-U) pipes - Test method for the resistance to dichloromethane at a specified temperature (DCMT)
  • EN 681-1:1996 Elastomeric Seals - Material Requirements for Pipe Joint Seals Used in Water and Drainage Applications - Part 1: Vulcanized Rubber (Incorporates Amendment A1: 1998)
  • EN 681-2:2000 Elastomeric seals - Materials requirements for pipe joint seals used in water and drainage applications - Part 2: Thermoplastic elastomers
  • EN 727:1994 Plastics piping and ducting systems - Thermoplastics pipes and fittings - Determination of Vicat softening temperature (VST)
  • EN 744:1995 Plastics piping and ducting systems - Thermoplastics pipes - Test method for resistance to external blows by the round-the-clock method
  • EN 922:1994 Plastics Piping and Ducting Systems - Pipes and Fittings of Unplasticized Poly(Vinyl Chloride) (PVC-U) - Specimen Preparation for Determination of the Viscosity Number and Calculation of the K-Value

EN 1329-1:2014 history

  • 2020 EN 1329-1:2020 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
  • 2014 EN 1329-1:2014 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
  • 1999 EN 1329-1:1999 Plastics Piping Systems for Soil and Waste Discharge (Low and High Temperature) within the Building Structure - Unplasticized Poly(Vinyl Chloride) (PVC-U) - Part 1: Specifications for Pipes, Fittings and the System



Copyright ©2024 All Rights Reserved