Scope
This part specifies the evaluation procedures for insulating structures subjected to thermal and electrical stress durability tests at the same time. The test procedures in this part are applicable to the formed winding insulation structure used or proposed for AC motors. The test procedures provide a comparison of the performance of the benchmark and the structure to be evaluated under the combination of voltage and temperature. In the past, temperature and voltage were used to evaluate performance separately. The temperature and voltage should be selected to cause failure of the structure under evaluation and the reference structure within a suitable time frame and under the stress of the actual application. The test results of the structure to be evaluated indicate whether it is better or worse than the reference structure proven by operating experience, but it cannot be used to calculate the operating life. The assessment of this standard does not include stress gradients. The test procedures in this section are not suitable for determining the interaction of thermal and electrical stress during aging and determining the durability curve. If additional information on the interaction is required or in order to determine the durability curve, further tests are necessary, either electrical aging at different voltages at constant temperature or thermal aging at different temperatures at constant voltage.

GB/T 17948.5-2016 Referenced Document

  • GB/T 11021-2007 Electrical insulation.Thermal classification
  • GB/T 17948.7-2016 Rotating electrical machines.Functional evaluation of insulation systems.General guidelines
  • GB/T 20112-2006 Evaluation and qualification of electrical insulation systems
  • GB/T 22715 Impulse voltage withstand levels of form-wound stator coils for rotating a. c. machines
  • GB/T 29310-2012 Guide for the statistical analysis of electrical insulation breakdown data
  • GB/Z 22720.2-2013 Rotating electrical machines.Qualification and acceptance tests for partial discharge resistant electrical insulation systems (Type II) used in rotating electrical machines fed from voltage converters

GB/T 17948.5-2016 history

  • 2016 GB/T 17948.5-2016 Rotating electrical machines.Functional evaluation of insulation systems.Test procedures for form-wound windings.Multifactor evaluation by endurance under simultaneous thermal and electrical stresses
  • 2007 GB/T 17948.5-2007 Rotating electrical machines.Functional evaluation of insulation systems.Test procedures for form-wound windings.Multifactor functional evaluation.Endurance under combined thermal and electrical stresses of insulation systems used in machines up to and in

GB/T 17948.5-2016 -All Parts




Copyright ©2024 All Rights Reserved