GB/T 7966-2009
Acoustics.Ultrasonics power measurement.Radiation force balances and performance requirements (English Version)

Standard No.
GB/T 7966-2009
Language
Chinese, Available in English version
Release Date
2009
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2022-10
Replace By
GB/T 7966-2022
Latest
GB/T 7966-2022
Replace
GB/T 7966-1987
Scope
This standard specifies the method for measuring the total radiated sound power of an ultrasonic transducer based on the use of a radiation force balance; establishes the principle of obtaining the sound field to be measured by the target and using the radiation force balance for measurement; clarifies the radiation force method when cavitation and Limits of use in the case of temperature rise; quantitative limits of use of the radiation force method in the presence of diverging and focused beams are identified; information is provided for the evaluation of all measurement uncertainties. This standard applies to: the measurement using a radiation force balance, the frequency range is from 0.5MHz-25MHz, and the ultrasonic power does not exceed 1W; the measurement using a radiation force balance, the frequency range is from 0.75MHz-5MHz, and the ultrasonic power does not exceed 20W; ultrasonic transducer The measurement of the total sound power of the instrument is more suitable for a well-collimated beam; use a gravity-type or force-feedback radiation force balance.

GB/T 7966-2009 Referenced Document

  • GB/T 15611-1995 Acoustics--Calibration of high frequency hydrophone
  • GB/T 16407-2006 Acoustics. Characteristics and measurements of field of pressure pulse lithotripters
  • GB/T 16540-1996 Acoustics--Measurement and characterisation of ultrasonic fields in the frequency range 0.5MHz to 15MHz--Hydrophone method
  • IEC 60050 International Electrotechnical Vocabulary (IEV) - Index
  • IEC 60050-801:1984 International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics
  • IEC 61101:1991 The absolute calibration of hydrophones using the planar scanning technique in the frequency range 0,5 MHz to 15 MHz
  • IEC 61689:1996 Ultrasonics - Physiotherapy systems - Performance requirements and methods of measurement in the frequency range 0,5 MHz to 5 MHz

GB/T 7966-2009 history

  • 2022 GB/T 7966-2022 Acoustics—Ultrasonic power measurement—Radiation force balances and the requirements
  • 2009 GB/T 7966-2009 Acoustics.Ultrasonics power measurement.Radiation force balances and performance requirements
  • 1987 GB/T 7966-1987 Acoustics--Ultrasonic power measurement in the frequency range 0.5~10MHz
Acoustics.Ultrasonics power measurement.Radiation force balances and performance requirements