These requirements cover cord-connected, relocatable power taps rated 250 V AC or less and 20 A AC or less. A relocatable power tap (RPT) is intended only for indoor use as a temporary extension of a grounding alternating-current branch circuit for general use. A cord-connected product with less than three receptacle outlets that employs an electromagnetic interference filter or a transient voltage surge suppressor is covered under the Standard for Electromagnetic Interference Filters, UL 1283, and the Standard for Surge Protective Devices, UL 1449, respectively. A cord-connected product with three or more receptacle outlets that employs an electromagnetic interference filter shall also comply with the Standard for Electromagnetic Interference Filters, UL 1283. A cord-connected product with three or more receptacle outlets that employs a transient voltage surge suppressor shall also comply with the Standard for Surge Protective Devices, UL 1449. Telephone equipment and communication circuit protectors included in a RPT shall comply with the requirements in the Standard for Telephone Equipment, UL 1459, and the requirements in the Standard for Secondary Protectors for Communications Circuits, UL 497A, respectively. A RPT that incorporates an antenna discharge unit or provides antenna connections to a television, a high-voltage video product, or antenna shall comply with the applicable requirements in the Standard for Antenna Discharge Units, UL 452, and the Standard for Audio-Video Products and Accessories, UL 1492. A cord-connected product that employs ground-fault protection is investigated under the requirements in the Standard for Ground-Fault Circuit Interrupters, UL 943. A cord-connected RPT is not intended to be connected to another cord-connected RPT. This standard does not cover RPTs intended for use with medical equipment. Medical equipment is typically intended for use in General Patient Care Areas or Critical Patient Care Areas as defined by Article 517 of the National Electrical Code for Health Care Facilities. RPTs intended for such use shall comply with the requirements of the Standard for Safety of Medical Electrical Equipment, Part 1: General Requirements, UL 60601-1 and the Standard for Safety Requirements for Medical Electrical Systems, IEC 60601-1-1. A RPT may employ non-electrical decorative features. The decorative features may include various shapes such as rocks, birds and animals, etc. These requirements do not cover Decorative Outfits Accessories. Decorative Outfits Accessories are investigated under the requirements in the Standard for Seasonal and Holiday Decorative Products, UL 588.
UL 1363-2007 history
2018UL 1363 BULLETIN-2018 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: May 21@ 2018)
2018UL 1363-2018 UL Standard for Safety Relocatable Power Taps (Fifth Edition)
2017UL 1363 CRD-2017 UL Standard for Safety Relocatable Power Taps - Section / Paragraph Reference: 13.8 and 48.24 Subject: RPT Employing Tamper Resistant Outlets (Edition 4: October 6@ 2014)
2017UL 1363 BULLETIN-2017 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: February 27@ 2017)
2016UL 1363 CRD-2016 UL Standard for Safety Relocatable Power Taps - Section / Paragraph Reference: Sections 1 (Scope); 3 (Glossary); Sections 11.1.7@ 12 (Construction) and 34 (Performance) Subject: Class 2 Lead (Edition 4: October 6@ 2014)
2015UL 1363 BULLETIN-2015 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: December 4@ 2015)
2014UL 1363 CRD-2014 UL Standard for Safety Relocatable Power Taps - Section/Paragraph Reference: 1.16@ 3.3 - 3.6@ 4.3 – 4.4@ 6.6 – 6.7@ Section 31.2@ Section 33A and Section 33B Subject: Pedestal Mounted Relocatable Power Taps (Edition 3: May 02@ 2007)
2014UL 1363 BULLETIN-2014 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: July 28@ 2014)
2014UL 1363-2014 UL Standard for Safety Relocatable Power Taps (Fourth Edition; Reprint with revisions through and including April 14@ 2017)
2013UL 1363 CRD-2013 UL Standard for Safety Relocatable Power Taps - Section / Paragraph Reference: New Paragraphs 17.12@ 21.1.11@ 21.2.9 and Section 36A Subject: Clarification of Requirements for RPTs with Moveable Parts Supersedes prior Certification Requirement Decision is
2013UL 1363 BULLETIN-2013 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: January 13@ 2014)
2012UL 1363 BULLETIN-2012 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: JUNE 20@ 2012)
2011UL 1363 BULLETIN-2011 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: April 11@ 2011)
2010UL 1363 BULLETIN-2010 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: October 04@ 2010)
2009UL 1363 BULLETIN-2009 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: October 26@ 2009)
2008UL 1363 CRD-2008 UL Standard for Safety Relocatable Power Taps - Section / Paragraph Reference: Paragraphs 13.2 and 14.8 Clarification of Paragraphs 13.2 and 14.8 (Edition 3: May 02@ 2007)
2008UL 1363 BULLETIN-2008 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: December 19@ 2008)
2007UL 1363 BULLETIN-2007 UL Standard for Safety Relocatable Power Taps COMMENTS DUE: January 21, 2008
2007UL 1363-2007 UL Standard for Safety Relocatable Power Taps Third Edition
2006UL 1363 BULLETINS-2006 UL Standard for Safety Relocatable Power Taps (10/27/2006 (4p); 06/30/2006 (8p))