UL 1363-2014
UL Standard for Safety Relocatable Power Taps (Fourth Edition; Reprint with revisions through and including April 14@ 2017)

Standard No.
UL 1363-2014
Release Date
2014
Published By
Underwriters Laboratories (UL)
Status
 2014-06
Replace By
UL 1363 BULLETIN-2014
Latest
UL 1363 BULLETIN-2018
Scope
These requirements cover indoor use cord and plug connected@ relocatable power taps (RPT) rated 250 V AC or less and 20 Amperes or less. A RPT may include an integral Class 2 power supply with an integral lead and/or connector(s) output. RPT are for use as a movable power supply connection for cord and plug connected electrical utilization equipment in accordance with the National Electric Code@ NFPA 70. A cord and plug connected product as described in 1.1 with less than three receptacle outlets and provided with a Luminaire is covered under the Standard for Portable Electric Luminaires@ UL 153. A cord and plug connected product as described in 1.1 with less than three receptacle outlets that employs an electromagnetic interference filter is covered under the Standard for Electromagnetic Interference Filters@ UL 1283. A cord and plug connected product as described in 1.1 with less than three receptacle outlets that employs a surge protective device (SPD) is covered under the Standard for Surge Protective Devices@ UL 1449. A cord and plug connected product as described in 1.1 that employs ground-fault protection is covered under the requirements for portable GFCIs in the Standard for Ground-Fault Circuit Interrupters@ UL 943. This standard does not cover RPT intended for use with medical equipment. A RPT may employ an integral cord reel for the supply cord and attachment plug. A cord reel provided with pull out receptacle outlets or cord connectors is covered under the Standard for Cord Reels@ UL 355. These requirements do not cover RPT??s with work surfaces or surfaces intended to support weight loads other than as specified in 3.11 for the storage of hand-held electronic devices and charging equipment such as a cell phone@ cell phone charger and the like. These requirements cover RPT??s provided with isolated secondary circuits. These requirements cover RPT??s provided with batteries located in isolated secondary circuits. See UL 1363 Supplement SB ?C Relocatable Power Taps Incorporating Batteries. A product that has a battery backup feature or other uninterruptible power supply equipment located in the Primary Circuit shall comply with the applicable requirements in the Standard for Uninterruptible Power Supply Equipment@ UL 1778. A RPT with three or more receptacle outlets may employ a Light Emitting Diode (LED) Luminaire.

UL 1363-2014 history

  • 2018 UL 1363 BULLETIN-2018 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: May 21@ 2018)
  • 2018 UL 1363-2018 UL Standard for Safety Relocatable Power Taps (Fifth Edition)
  • 2017 UL 1363 CRD-2017 UL Standard for Safety Relocatable Power Taps - Section / Paragraph Reference: 13.8 and 48.24 Subject: RPT Employing Tamper Resistant Outlets (Edition 4: October 6@ 2014)
  • 2017 UL 1363 BULLETIN-2017 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: February 27@ 2017)
  • 2016 UL 1363 CRD-2016 UL Standard for Safety Relocatable Power Taps - Section / Paragraph Reference: Sections 1 (Scope); 3 (Glossary); Sections 11.1.7@ 12 (Construction) and 34 (Performance) Subject: Class 2 Lead (Edition 4: October 6@ 2014)
  • 2016 UL 1363 BULLETIN-2016 UL Standard for Safety Relocatable Power Taps
  • 2015 UL 1363 BULLETIN-2015 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: December 4@ 2015)
  • 2014 UL 1363 CRD-2014 UL Standard for Safety Relocatable Power Taps - Section/Paragraph Reference: 1.16@ 3.3 - 3.6@ 4.3 – 4.4@ 6.6 – 6.7@ Section 31.2@ Section 33A and Section 33B Subject: Pedestal Mounted Relocatable Power Taps (Edition 3: May 02@ 2007)
  • 2014 UL 1363 BULLETIN-2014 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: July 28@ 2014)
  • 2014 UL 1363-2014 UL Standard for Safety Relocatable Power Taps (Fourth Edition; Reprint with revisions through and including April 14@ 2017)
  • 2013 UL 1363 CRD-2013 UL Standard for Safety Relocatable Power Taps - Section / Paragraph Reference: New Paragraphs 17.12@ 21.1.11@ 21.2.9 and Section 36A Subject: Clarification of Requirements for RPTs with Moveable Parts Supersedes prior Certification Requirement Decision is
  • 2013 UL 1363 BULLETIN-2013 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: January 13@ 2014)
  • 2012 UL 1363 BULLETIN-2012 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: JUNE 20@ 2012)
  • 2011 UL 1363 BULLETIN-2011 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: April 11@ 2011)
  • 2010 UL 1363 BULLETIN-2010 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: October 04@ 2010)
  • 2009 UL 1363 BULLETIN-2009 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: October 26@ 2009)
  • 2008 UL 1363 CRD-2008 UL Standard for Safety Relocatable Power Taps - Section / Paragraph Reference: Paragraphs 13.2 and 14.8 Clarification of Paragraphs 13.2 and 14.8 (Edition 3: May 02@ 2007)
  • 2008 UL 1363 BULLETIN-2008 UL Standard for Safety Relocatable Power Taps (COMMENTS DUE: December 19@ 2008)
  • 2007 UL 1363 BULLETIN-2007 UL Standard for Safety Relocatable Power Taps COMMENTS DUE: January 21, 2008
  • 2007 UL 1363-2007 UL Standard for Safety Relocatable Power Taps Third Edition
  • 2006 UL 1363 BULLETINS-2006 UL Standard for Safety Relocatable Power Taps (10/27/2006 (4p); 06/30/2006 (8p))
  • 2005 UL 1363 BULLETIN-2005 UL Standard for Safety Relocatable Power Taps
  • 2004 UL 1363 BULLETINS-2004 04/06/2004 (10p)
  • 2003 UL 1363 BULLETINS-2003 12/23/2003 (6p); 10/20/2003 (4p); 07/25/2001 (6p)
  • 2001 UL 1363 BULLETIN-2001 UL Standard for Safety Relocatable Power Taps
  • 1996 UL 1363-1996 Relocatable temporary power taps
  • 1991 UL 1363-1991 Temporary power taps



Copyright ©2024 All Rights Reserved