GB/T 2820.7-2002
Reciprocating internal combustion engine driven alternating current generating sets Part 7: Technical declarations for specification and design (English Version)

Standard No.
GB/T 2820.7-2002
Language
Chinese, Available in English version
Release Date
2002
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 2820.7-2002
Scope
This standard refers to the relevant definitions given in GB/T 2820.1~2820.6, and specifies the technical conditions and design requirements for generator sets driven by reciprocating internal combustion engines (RIC). This standard applies to alternating current (aC) generator sets driven by land and marine reciprocating internal combustion engines (RIC). Not applicable to generating sets for aviation or driving land vehicles and locomotives. For generator sets for some special purposes (such as power supply for hospitals, high-rise buildings, etc.), it is necessary to put forward some supplementary requirements. The relevant provisions of this standard can be used as a basis. For other types of prime movers (such as biogas engines, steam engines, etc.), the relevant provisions of this standard should also be used as the basis.

GB/T 2820.7-2002 history

  • 2002 GB/T 2820.7-2002 Reciprocating internal combustion engine driven alternating current generating sets Part 7: Technical declarations for specification and design
Reciprocating internal combustion engine driven alternating current generating sets Part 7: Technical declarations for specification and design

GB/T 2820.7-2002 -All Parts

GB/T 2820.1-2022 Alternating generator sets driven by reciprocating internal combustion engines - part 1: use, ratings and performance GB/T 2820.10-2002 Reciprocating internal combustion engine driven alternating current generating sets Part 10: Measurement of airborne noise by the enveloping surface method GB/T 2820.11-2012 Reciprocating internal combustion engine driven alternating current generating sets.Part 11:Rotary uninterruptible power systems.Performance requirements and test methods GB/T 2820.12-2002 Reciprocating internal combustion engine driven alternating current generating sets--Part 12: Emergency power supply to safty services GB/T 2820.2-2009 Reciprocating internal combustion engine driven alternating current generating sets.Part 2:Engines GB/T 2820.3-2009 Reciprocating internal combustion engine driven alternating current generating sets.Part 3:Alternating current generators for generating sets GB/T 2820.4-2009 Reciprocating internal combustion engine driven alternating current generating sets.Part 4:Controlgear and switchgear GB/T 2820.5-2009 Reciprocating internal combustion engine driven alternating current generating sets.Part 5:Generating sets GB/T 2820.6-2009 Reciprocating internal combustion engine driven alternating current generating sets.Part 6:Test methods GB/T 2820.7-2002 Reciprocating internal combustion engine driven alternating current generating sets Part 7: Technical declarations for specification and design GB/T 2820.8-2022 Alternating generator sets driven by reciprocating internal combustion engines - Part 8: Requirements and tests for low power generator sets GB/T 2820.9-2002 Reciprocating internal combustion engine driven alternating current generating sets--Part 9: Measurement and evaluation of mechanical vibrations



Copyright ©2024 All Rights Reserved