DIN EN 1090-4:2018
Execution of steel structures and aluminium structures - Part 4: Technical requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor and wall applications; German version EN 1090-4:2018

Standard No.
DIN EN 1090-4:2018
Release Date
2018
Published By
German Institute for Standardization
Status
Replace By
DIN EN 1090-4/A100 E:2019
Latest
DIN EN 1090-4:2020-06
Replace
DIN 18807-3:1987 DIN 18807-3/A1:2001 DIN EN 1090-4:2015
Scope
This European Standard specifies requirements for the execution, i.e. the manufacture and the installation, of cold-formed structural steel members and sheeting and cold-formed structures for roof, ceiling, floor, wall and cladding applications. This European Standard applies to structures designed according to the EN 1993 series. This European Standard applies to structural members and sheeting to be designed according to EN 1993-1-3. This European Standard may be used for structures designed according to other design rules provided that conditions for execution comply with them and any necessary additional requirements are specified. This European Standard also specifies requirements for the execution i.e. the manufacture and the installation of structures made from cold formed profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading or seismic loading conditions and their documentation. This European Standard covers sheeting of structural classes I and II according to EN 1993-1-3 used in structures. This European Standard covers structural members of all structural classes according to EN 1993-1-3.

DIN EN 1090-4:2018 Referenced Document

  • ASTM A380-06 Standard Practice for Cleaning, Descaling, and Passivation of Stainless Steel Parts, Equipment, and Systems*2024-04-20 Update
  • ASTM D5796-10 Standard Test Method for Measurement of Dry Film Thickness of Thin Film Coil-Coated Systems by Destructive Means Using a Boring Device*2024-04-20 Update
  • EN 1090-5:2017 Execution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof@ ceiling@ floor and wall applications
  • EN 1990:2002 Eurocode: Basis of structural design
  • EN 1991 Eurocode 1 - Actions on structures - Part 4: Silos and tanks
  • EN 1991-1-1:2002 Eurocode 1: Actions on structures - Part 1-1: General actions - Densities, self-weight and imposed loads for buildings
  • EN 1991-1-2:2002 Eurocode 1: Actions on structures - Part 1-2: General actions - Actions on structures exposed to fire*2024-04-20 Update
  • EN 1991-1-3:2003 Eurocode 1 - Actions on structures - Part 1-3: General actions - Snow loads
  • EN 1991-1-4:2005 Eurocode 1: Actions on structures - Part 1-4: General actions - Wind actions
  • EN 1991-1-5:2003 Eurocode 1: Actions on structures - Part 1-5: General actions; Thermal actions*2024-04-20 Update
  • EN 1991-1-6:2005 Eurocode 1 - Actions on structures Part 1-6: General actions - Actions during execution
  • EN 1991-1-7:2006 Eurocode 1 - Actions on structures - Part 1-7: General actions - Accidental actions
  • EN 1991-2:2003 Eurocode 1: Actions on structures - Part 2: Traffic loads on bridges
  • EN 1991-3:2006 Eurocode 1 - Actions on structures - Part 3: Actions induced by cranes and machinery
  • EN 508-1:2014 Roofing and cladding products from metal sheet - Specification for self-supporting of steel, aluminium or stainless steel sheet - Part 1: Steel
  • EN 508-3:2008 Roofing products from metal sheet - Specification for self-supporting products of steel, aluminium or stainless steel sheet - Part 3: Stainless steel

DIN EN 1090-4:2018 history

  • 2020 DIN EN 1090-4:2020-06 Execution of steel structures and aluminium structures - Part 4: Technical requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor and wall applications; German version EN 1090-4:2018
  • 2020 DIN EN 1090-4:2020 Execution of steel structures and aluminium structures - Part 4: Technical requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor and wall applications
  • 1970 DIN EN 1090-4 A100 E:2019-04
  • 2019 DIN EN 1090-4/A100 E:2019 Draft Document - Execution of steel structures and aluminium structures - Part 4: Technical requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor and wall applications; German version EN 1090-4:2018;...
  • 2018 DIN EN 1090-4:2018 Execution of steel structures and aluminium structures - Part 4: Technical requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor and wall applications; German version EN 1090-4:2018
  • 1970 DIN EN 1090-4 E:2015-11 Execution of steel structures and aluminium structures - Part 4: Technical requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor and wall applications
  • 2015 DIN EN 1090-4 E:2015 Draft Document - Execution of steel structures and aluminium structures - Part 4: Technical requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor and wall applications; German and English version prE...
  • 1970 DIN EN 1090-4 E:2014-06 Execution of steel structures and aluminium structures - Part 4: Technical requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor and wall applications
  • 2001 DIN 18807-3/A1:2001 Trapezoidal sheeting in building - Steel trapezoidal sheeting - Analysis, structural and design; Amendment A1
  • 1987 DIN 18807-3:1987 Trapezoidal sheeting in building; trapezoidal steel sheeting; structural analysis and design
Execution of steel structures and aluminium structures - Part 4: Technical requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor and wall applications; German version EN 1090-4:2018