EN 1090-5:2017
Execution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof@ ceiling@ floor and wall applications

Standard No.
EN 1090-5:2017
Release Date
2017
Published By
European Committee for Standardization (CEN)
Latest
EN 1090-5:2017
Replace
FprEN 1090-5-2016
Scope
This European Standard specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium components made from profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading conditions or seismic loading conditions and their documentation. It does cover products of structural class I and II according to EN 1999-1-4 used in structures. Structural elements are understood here to mean profiled sheeting, such as trapezoidal, sinusoidal, liner trays or cassette profiles, that are produced by cold forming. Perforated and micro profiled sheeting are also covered by this part. Welded sections are excluded from this part and are covered by EN 1090-3 except seal welding in low-stress areas. This standard also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements. A combination of steel and aluminium structural elements are permitted, e. g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090-4 and this document apply. Composite structural elements where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard. NOTE The structures covered in this standard can be for example - single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural elements; - single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural elements; or; - suspended ceilings for interior fitting.

EN 1090-5:2017 Referenced Document

  • ASTM D5796-10 Standard Test Method for Measurement of Dry Film Thickness of Thin Film Coil-Coated Systems by Destructive Means Using a Boring Device*2024-04-20 Update
  • EN 1090-3:2008 Execution of steel structures and aluminium structures - Part 3: Technical requirements for aluminium structures
  • EN 1090-4 Execution of steel structures and aluminium structures - Part 4: Technical requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor and wall applications*2018-07-04 Update
  • EN 1396:2015 Aluminium and aluminium alloys - Coil coated sheet and strip for general applications - Specifications
  • EN 1990:2002 Eurocode: Basis of structural design
  • EN 1991-1-1:2002 Eurocode 1: Actions on structures - Part 1-1: General actions - Densities, self-weight and imposed loads for buildings
  • EN 1991-1-2:2002 Eurocode 1: Actions on structures - Part 1-2: General actions - Actions on structures exposed to fire*2024-04-20 Update
  • EN 1991-1-3:2003 Eurocode 1 - Actions on structures - Part 1-3: General actions - Snow loads
  • EN 1991-1-4:2005 Eurocode 1: Actions on structures - Part 1-4: General actions - Wind actions
  • EN 1991-1-5:2003 Eurocode 1: Actions on structures - Part 1-5: General actions; Thermal actions*2024-04-20 Update
  • EN 1991-1-6:2005 Eurocode 1 - Actions on structures Part 1-6: General actions - Actions during execution
  • EN 1991-1-7:2006 Eurocode 1 - Actions on structures - Part 1-7: General actions - Accidental actions
  • EN 1992-1-1:2004 Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings*2024-04-20 Update
  • EN 1992-1-2:2004 Eurocode 2: Design of concrete structures - Part 1-2: General rules - Structural fire design*2024-04-20 Update
  • EN 1992-2:2005 Eurocode 2 - Design of concrete structures - Concrete bridges - Design and detailing rules*2024-04-20 Update
  • EN 1992-3:2006 Eurocode 2 - Design of concrete structures - Part 3: Liquid retaining and containment structures
  • EN 1993-1-1:2005 Eurocode 3: Design of steel structures - Part 1-1: General rules and rules for buildings
  • EN 1993-1-3:2006 Eurocode 3 - Design of steel structures - Part 1-3: General rules - Supplementary rules for cold-formed members and sheeting*2024-04-20 Update
  • EN 1993-1-4:2006 Eurocode 3 - Design of steel structures - Part 1-4: General rules - Supplementary rules for stainless steels*2024-04-20 Update
  • EN 1993-1-5:2006 Eurocode 3 - Design of steel structures - Part 1-5: Plated structural elements*2024-04-20 Update
  • EN 1995-1-1:2004 Eurocode 5 - Design of timber structures - Part 1-1: General - Common rules and rules for buildings*2024-04-20 Update
  • EN 508-2:2008 Roofing products from metal sheet - Specification for self-supporting products of steel, aluminium or stainless steel sheet - Part 2: Aluminium

EN 1090-5:2017 history

  • 2017 EN 1090-5:2017 Execution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof@ ceiling@ floor and wall applications