GB/T 32520-2016
Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV (English Version)

Standard No.
GB/T 32520-2016
Language
Chinese, Available in English version
Release Date
2016
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2024-10
Replace By
GB/T 32520-2024
Latest
GB/T 32520-2024
Scope
This standard applies to external series gap metal oxide surge arresters without insulating support (hereinafter referred to as external gap line arresters, EGLA) for overhead transmission and distribution lines above AC 1 kV, only protecting line insulation [including insulators (strings) and air Clearance] from flashover or breakdown caused by lightning. Since the metal oxide resistors of EGLA are connected to the line through the outer series gap, the following issues will not be considered in this standard: --Operating impulse discharge voltage; --Steep wave and operating impulse residual voltage; --Thermal stability; -- - Long-term continuous current impact resistance; - Lightning arrester power frequency voltage withstand time characteristics; - Disconnector test; - Aging caused by power frequency voltage. Considering the specific design concept and special application of overhead transmission and distribution lines, some unique requirements and tests are introduced, such as verification test of insulation coordination between insulator withstand and EGLA protection level, freewheeling interruption test, mechanical load test, etc. .

GB/T 32520-2016 Referenced Document

  • GB 11032-2010 Metal-oxide surge arresters without gaps for a.c. systems
  • GB 311.1 Insulation co-ordination.Part 1:Definitions,principles and rules
  • GB/T 16422.1-2006 Plastics. Methods of the exposure to laboratory light sources. Part 1: General guidance
  • GB/T 16422.2-2014 Plastics.Methods of exposure to laboratory light sources.Part 2:Xenon-arc sources
  • GB/T 16422.3-2014 Plastics.Methods of exposure to laboratory light sources.Part 3 :Fluorescent UV lamps
  • GB/T 16927.1 High-voltage test techniques.Part 1:General definitions and test requirements
  • GB/T 16927.2 High-voltage test techniques.Part 2:Measuring systems
  • GB/T 191-2008 Packaging.Pictorial marking for handling of goods
  • GB/T 22079-2008 Polymeric insulators for indoor and out door use with a nominal voltage >1000 V. General definitions, test methods and acceptance criteria
  • GB/T 2317.2 Test methods for electrical fittings - Part 2: Corona and radio disturbance tests
  • GB/T 2423.17-2008 Environmental testing for electric and electronic products.Part 2:Test method.Test Ka:Salt mist
  • GB/T 2423.22-2012 Environmental testing.Part 2:Test methods.Test N:Change of temperature
  • GB/T 262 Petroleum products and hydrocarbon solvents.Determination of aniline point and mixed aniline point
  • GB/T 2900.12-2008 Electrotechnical terminology.Surge arresters,low-voltage surge protective devices and components
  • GB/T 2900.19-1994 Electrotechnical terminology.High-voltage test technique and insulation co-ordination
  • GB/T 4585-2004 Artificial pollution tests on high-voltage insulators to be used on a.c systems
  • GB/T 7354-2003 Partial discharge measurements

GB/T 32520-2016 history

  • 2024 GB/T 32520-2024 Out-of-band series gap metal oxide surge arresters (EGLA) for overhead transmission and distribution lines above 1 kV AC
  • 2016 GB/T 32520-2016 Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV