ASTM F2660-12
Standard Test Method for Qualifying Coatings for Use on A490 Structural Bolts Relative to Hydrogen Embrittlement

Standard No.
ASTM F2660-12
Release Date
2012
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM F2660-13
Latest
ASTM F2660-20
Scope
1.1 This test method defines the procedures and tests to evaluate the effect of a coating system on the susceptibility to environmental hydrogen embrittlement (EHE) of an ASTM A490 high strength structural bolt.

1.2 This test method shall qualify a coating system for use with any size of A490 bolts (that is, 1/2 to 1-1/2 in.) high strength structural bolts, relative to EHE.

1.3 The characteristic to be evaluated by this test method is the susceptibility to EHE caused by hydrogen generated from corrosion protection of the steel bolt by sacrificial galvanic corrosion of the coating. Testing shall be performed on coated, specimen ASTM A490 bolts manufactured to the maximum susceptible tensile strength values (see Table 1) of the bolt (see Section 5 Specimen Bolt Requirements). The internal hydrogen embrittlement (IHE) susceptibility will also be inherently evaluated when the EHE is tested through this test method. There is no need for a separate IHE susceptibility test.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM F2660-12 history