This document applies to water meters intended for residential,commercial,light industrial and industrial use,and specifies the test parameters and the test methods for water meters,irrespective of the design technologies ,as specified in EN 14154-1-2005+A2,used to meter the actual volume of clean cold potable water or heated water,flowing through a fully charged,closed conduit.These water meters shall incorporate devices,which indicate the integrated volume.
In the case where water meters having a value of Q>160m/h,the test schedule may make provisions for modification of the Reference Conditions,to meet individual test laboratory limitations,when testing specifically for endurance or for performance under Influence Quantities.
Meters thus tested shall be marked so as to unambiguously indicate part compliance with this document. To augment this marking the meter manufacturer shall, in addition, be obliged to fully disclose the specific non compliance(s) due to the test laboratory limitations.
DIN EN 14154-3:2011 Referenced Document
EN 60068-1:1994 Environmental Testing Part 1: General and Guidance (Remains Current)
EN 60068-2-2:1993 Basic Environmental Testing Procedures Part 2: Tests Tests B : Dry Heat (Incorporates Amendment A1: 1993)
EN 60068-2-30:1999 Environmental Testing - Part 2: Tests - Test Db and Guidance: Damp Heat@ Cyclic (12 + 12 Hour Cycle)
EN 60068-2-31:1993 Basic Environmental Testing Procedures Part 2: Tests Test Ec: Drop and Topple@ Primarily for Equipment- Type Specimens
EN 60068-2-47:1999 Environmental Testing - Part 2-47: Test Methods - Mounting of Components@ Equipment and Other Articles for Vibration@ Impact and Similar Dynamic Tests
EN 60068-2-64:1994 Environmental testing Part 2: Test methods Test Fh: Vibration, broad-band random (digital control) and guidance (IEC 68-2-64:1993 + corrigendum 1993)
EN 60068-3-1:1999 Environmental Testing Part 3: Background Information Section 1: Cold and Dry Heat Tests
EN 61000 Electromagnetic compatibility (EMC) - Part 6-7: Generic standards - Immunity requirements for equipment intended to perform functions in a safety-related system (functional safety) in industrial locations*, 2015-05-01 Update
EN 61000-4-2:1995 Electromagnetic Compatibility (EMC) - Part 4.2: Testing and Measurement Techniques - Electrostatic Discharge Immunity Test Includes Amendments A1:1998 and A2:2001; IEC 61000-4-2:1995 + A1:1998 + A2:2000
EN 61000-4-3:1996 Electromagnetic Compatibility (EMC) - Part 4-3: Testing and Measurement Techniques - Radiated@ Radio-Frequency@ Electromagnetic Field Immunity Test (Incorporates Amendments A1: 1998 and A2: 2001)
DIN EN 14154-3:2011 history
2014DIN EN ISO 4064-2:2014 Water meters for cold potable water and hot water - Part 2: Test methods (ISO 4064-2:2014); German version EN ISO 4064-2:2014
2011DIN EN 14154-3:2011 Water meters - Part 3: Test methods and equipment; German version EN 14154-3:2005+A2:2011
2007DIN EN 14154-3:2007 Water meters - Part 3: Test methods and equipment German version EN 14154-3:2005+A1:2007