For the purpose of determining compliance with the specified limits for requirements of the properties listed in the following table, an observed value or a calculated value shall be rounded as indicated in accordance with the rounding method of Practice E 29
Property Rounded Unit for Observed or
Calculated Value Chemical composition nearest unit in the last right-hand place of Hardness figures of the specified limit Tensile strength nearest ksi (5 MPa)
1.1 This specification establishes the requirements for seamless copper tube (DWV) produced from Copper UNS No. C12200 and intended for sanitary drainage, waste, and vent piping.
Note 18212;Fittings used for soldered or brazed connections in drainage, waste, or vent systems are described in ASME Standards B16.23 and B16.29 and CSA Standard B158.1.
Note 28212;The assembly of copper drainage, waste, and vent systems by soldering is described in Practice B 828 Note 38212;Solders for joining copper drainage, waste, or vent systems are described in Specification B 32
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 The following hazard statement pertains only to the test method described in Section 16.2.3 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.