GB/T 16841-2008
Guide for dosimetry in an electron beam facility for radiation processing at energies between 300 keV~25MeV (English Version)

Standard No.
GB/T 16841-2008
Language
Chinese, Available in English version
Release Date
2008
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 16841-2008
Replace
GB/T 16841-1997
Scope
1.1 This standard specifies the dose measurement involved in installation confirmation, operation confirmation, performance confirmation (IQ, OQ and PQ) and daily processing in order to ensure that all products receive the dose required to produce the expected radiation effect in electron beam radiation processing procedures, and other procedures that may affect these processes and are used to monitor absorbed doses in products. 1.2 The energy range of electron beams applicable to this standard: 300keV~25MeV. 1.3 Dose measurement is only one part of the total quality management of irradiation processing. In special applications such as radiation sterilization of medical and health care products and food preservation, other measurements are required in addition to dosimetry. 1.4 ISO and ASTM have published specific standards applicable to food irradiation and healthcare products. See ISO/ASTM 51431 for specific standards for food irradiation, and GB 18280 for specific standards for radiation sterilization of medical and healthcare products. In use, the provisions of GB 18280 take precedence over the provisions of other standards. 1.5 This standard does not address safety issues related to use. The user of this standard is responsible for establishing applicable safety and health standards and determining applicable limitations prior to use.

GB/T 16841-2008 Referenced Document

  • ASTM E1026 Standard Practice for Using the Fricke Reference Standard Dosimetry System
  • ASTM E170 Standard Terminology Relating to Radiation Measurements and Dosimetry
  • ASTM E2232 Standard Guide for Selection and Use of Mathematical Methods for Calculating Absorbed Dose in Radiation Processing Applications*2021-06-15 Update
  • ASTM E2303 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities*2024-04-19 Update
  • GB 18280 Sterilization of health care products--Requirement for validation and routine control--Radiation sterilization
  • GB/T 16509 Standard guide for estimating uncertainties in dosimetry for radiation processing
  • GB/T 16510 The requirements for the competence of a radiation processing dosimetry calibration laboratory
  • GB/T 16639 Standard method for use of an alanine-EPR dosimetry system
  • GB/T 16640 Standard guide for selection and calibration of dosimetry systems for radiation processing
  • ISO/ASTM 51205 Practice for use of a ceric-cerous sulfate dosimetry system*2017-05-01 Update
  • ISO/ASTM 51275 Practice for use of a radiochromic film dosimetry system*2013-06-01 Update
  • ISO/ASTM 51276 Practice for use of a polymethylmethacrylate dosimetry system*2019-08-14 Update
  • ISO/ASTM 51401 Practice for use of a dichromate dosimetry system*2013-11-15 Update
  • ISO/ASTM 51431 Practice for dosimetry in electron beam and X-ray (bremsstrahlung) irradiation facilities for food processing
  • ISO/ASTM 51538 Practice for use of the ethanol-chlorobenzene dosimetry system*2017-10-03 Update
  • ISO/ASTM 51539 Guidance for use of radiation-sensitive indicators*2023-05-01 Update
  • ISO/ASTM 51540 Practice for use of a radiochromic liquid dosimetry system
  • ISO/ASTM 51631 Practice for use of calorimetric dosimetry systems for dose measurements and dosimetry system calibration in electron beams*2020-02-25 Update
  • ISO/ASTM 51956 Practice for use of a thermoluminescence-dosimetry system (TLD system) for radiation processing*2013-11-15 Update

GB/T 16841-2008 history

  • 2008 GB/T 16841-2008 Guide for dosimetry in an electron beam facility for radiation processing at energies between 300 keV~25MeV
  • 1997 GB/T 16841-1997 Guide for dosimetry in an electron beam facility for radiation processing at energies between 300keV and 25MeV
Guide for dosimetry in an electron beam facility for radiation processing at energies between 300 keV~25MeV