UL 61010-031-2007
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test

Standard No.
UL 61010-031-2007
Release Date
2007
Published By
Underwriters Laboratories (UL)
Status
Replace By
UL 61010-031 (ND)-2007
Latest
UL 61010-031-2020
Scope
The document specifies safety requirements for probe assemblies for (electrical) measurement and test. It applies to hand-held and hand-manipulated probe assemblies of the types described below, and related accessories which are intended for professional, industrial process, and educational use. These probe assemblies are for use in the interface between an electrical phenomenon and test or measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. a) Low-voltage and high-voltage, non-attenuating probe assemblies (type A). Non-attenuating probe assemblies that are rated for direct connection to voltages exceeding 33 V r.m.s. or 46,7 V peak or 70 V d.c., but not exceeding 63 kV. They do not incorporate active components, nor are they intended to provide a voltage divider function or a signal conditioning function, but they may contain passive non-attenuating components such as fuses. b) High-voltage attenuating or divider probe assemblies (type B). Attenuating or divider probe assemblies that are rated for direct connection to secondary voltages exceeding 1 kV but not exceeding 63 kV. The divider function may be carried out wholly within the probe assemblies, or partly within the test or measurement equipment to be used with the probe assemblies. c) Low-voltage attenuating or divider probe assemblies (type C). Attenuating, divider or other signal conditioning probe assemblies for direct connection to voltages exceeding 33 V r.m.s or 46,7 V peak or 70 V d.c., but not exceeding 1 kV r.m.s. or 1,5 kV d.c. The signal conditioning function may be carried out wholly within the probe assemblies, or partly within the test or measurement equipment intended to be used with the probe assemblies. This standard does not cover a) reliable function, performance or other properties of the probe assembly; b) effectiveness of transport packaging; c) servicing (repair); d) protection of servicing (repair) personnel.

UL 61010-031-2007 history

  • 1970 UL 61010-031-2020 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test
  • 2017 UL 61010-031 (ND)-2017 National Differences For Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety Requirements for Hand-Held Probe Assemblies for Electrical Measurement and Test (Second Edition)
  • 2017 UL 61010-031-2017 UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (Second Edition)
  • 2016 UL 61010-031 BULLETIN-2016 UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety Requirements for Hand-Held Probe Assemblies for Electrical Measurement and Test (COMMENTS DUE: NOVEMBER 14@ 2016)
  • 2014 UL 61010-031 BULLETIN-2014 UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (COMMENTS DUE: OCTOBER 27@ 2014)
  • 2010 UL 61010-031 BULLETIN-2010 UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (COMMENTS DUE: March 08@ 2010)
  • 2009 UL 61010-031 BULLETIN-2009 UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (COMMENTS DUE: October 05@ 2009)
  • 2007 UL 61010-031 (ND)-2007 National Differences For UL 61010-031 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and (First Edition; Reprint with Revis
  • 2007 UL 61010-031-2007 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test



Copyright ©2024 All Rights Reserved