UL 61010-031 BULLETIN-2016
UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety Requirements for Hand-Held Probe Assemblies for Electrical Measurement and Test (COMMENTS DUE: NOVEMBER 14@ 2016)

Standard No.
UL 61010-031 BULLETIN-2016
Release Date
2016
Published By
Underwriters Laboratories (UL)
Status
 2017-02
Replace By
UL 61010-031-2017
Latest
UL 61010-031-2020
Scope
Probe assemblies included in scope This part of IEC 61010 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below@ and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. a) Type A: low-voltage and high-voltage@ non-attenuating probe assemblies. Non-attenuating probe assemblies that are RATED for direct connection to voltages exceeding 30 V r.m.s.@ 42@4 V peak@ or 60 V d.c.@ but not exceeding 63 kV. They do not incorporate components which are intended to provide a voltage divider function or a signal conditioning function@ but they may contain non-attenuating components such as fuses (see Figure 1.) b) Type B: high-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies that are RATED for direct connection to secondary voltages exceeding 1 kV r.m.s. or 1@5 kV d.c. but not exceeding 63 kV r.m.s. or d.c. The divider function may be carried out wholly within the probe assembly@ or partly within the test or measurement equipment to be used with the probe assembly (see Figure 2). c) Type C: low-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies for direct connection to voltages not exceeding 1 kV r.m.s. or 1@5 kV d.c. The signal conditioning function may be carried out wholly within the probe assembly@ or partly within the test or measurement equipment intended to be used with the probe assembly (see Figure 3). d) Type D: low-voltage attenuating@ non-attenuating or other signal conditioning probe assemblies@ that are RATED for direct connection only to voltages not exceeding 30 V r.m.s.@ or 42@4 V peak@ or 60 V d.c.@ and are suitable for currents exceeding 8 A (see Figure 4). Probe assemblies excluded from scope This standard does not apply to current sensors within the scope of IEC 61010-2-032 (Handheld and hand-manipulated current sensors)@ but may apply to their input measuring circuit leads and accessories.

UL 61010-031 BULLETIN-2016 history

  • 1970 UL 61010-031-2020 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test
  • 2017 UL 61010-031 (ND)-2017 National Differences For Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety Requirements for Hand-Held Probe Assemblies for Electrical Measurement and Test (Second Edition)
  • 2017 UL 61010-031-2017 UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (Second Edition)
  • 2016 UL 61010-031 BULLETIN-2016 UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety Requirements for Hand-Held Probe Assemblies for Electrical Measurement and Test (COMMENTS DUE: NOVEMBER 14@ 2016)
  • 2014 UL 61010-031 BULLETIN-2014 UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (COMMENTS DUE: OCTOBER 27@ 2014)
  • 2010 UL 61010-031 BULLETIN-2010 UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (COMMENTS DUE: March 08@ 2010)
  • 2009 UL 61010-031 BULLETIN-2009 UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control and Laboratory Use – Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (COMMENTS DUE: October 05@ 2009)
  • 2007 UL 61010-031 (ND)-2007 National Differences For UL 61010-031 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and (First Edition; Reprint with Revis
  • 2007 UL 61010-031-2007 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test



Copyright ©2024 All Rights Reserved