JB/T 6213.3-2006
Flexiuie cables and cords for winding leads of electric motors Part 3: Flexible cables and cords with maximum continuous operating temperature of 90℃ (English Version)

Standard No.
JB/T 6213.3-2006
Language
Chinese, Available in English version
Release Date
2006
Published By
Professional Standard - Machinery
Latest
JB/T 6213.3-2006
Replace
JB/T 6213.3-1992
Scope
This part of JB/T 6213 specifies the models, specifications, technical requirements and inspections of motor winding lead flexible cables and cords with a maximum conductor temperature of 90°C for continuous operation. This section applies to motor winding lead flexible cables and cords with a maximum conductor temperature of 90°C in continuous operation. This section should be used in conjunction with JB/T 6213.1.

JB/T 6213.3-2006 Referenced Document

  • GB/T 12706.2-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV)up to 35kV(Um=40.5kV) Part 2:Cables for rated voltages from 6kV(Um=7.2kV)up to 30kV(Um=36kV)
  • GB/T 2951.1-1997 Common test methods for insulating and sheathing materials of electric cables. Part 1: Methods for general application. Section one: Measurement of thickness and overall dimensions--Tests for determining the mechanical properties
  • GB/T 2951.2-1997 Common test methods for insulating and sheating materials of electric cables. Part 1: Methods for general application. Section two: Thermal ageing methods
  • GB/T 2951.5-1997 Common test methods for insulating and sheathing materials of electric cables. Part 2: Methods specific to elastomeric compounds. Section one: Ozone resistance test--Hot set test--Mineral oil immersion test
  • GB/T 3048.4-1994 Test methods for determining electrical properties of electric cables and wires.Measurement of D.C. resistance of conductors
  • GB/T 3048.8-1994 Test methods for determining electrical properties of electric cables and wires.A.C. voltage tests
  • GB/T 3048.9-1994 Test methods for determining electrical properties of electric cables and wires.A.C. spark test of insulated cores
  • JB/T 6213.1-2006 Flexible cables and cords for winding leads of electric motors Part 1: General

JB/T 6213.3-2006 history

  • 2006 JB/T 6213.3-2006 Flexiuie cables and cords for winding leads of electric motors Part 3: Flexible cables and cords with maximum continuous operating temperature of 90℃
  • 1992 JB/T 6213.3-1992 Flexible cables and cords for electrical machine winding connections Part 3: Flexible cables and cords with a maximum conductor temperature of 90°C for continuous operation
Flexiuie cables and cords for winding leads of electric motors Part 3: Flexible cables and cords with maximum continuous operating temperature of 90℃