This part of JB/T 6213 specifies product markings and marking examples, technical requirements, test methods, inspection rules, markings, and packaging of flexible cables and cords leading to motor windings. The technical requirements for flexible cables and cords leading to various types of motor windings are specified in the various parts of JB/T 6213.2~6213.6. This section applies to non-detachable flexible cables and cords connected to the motor windings, with the other end connected to the terminal base of the motor housing or directly led out of the housing. The flexible cables and cords leading to the motor windings are referred to as cables (wires) in this section.
JB/T 6213.1-2006 Referenced Document
GB 6995.1 Markings for electric cables and wires--Part 1:General requirements
GB 6995.2 Markings for electric cables and wires--Part 2:Standard colours
GB 6995.3 Markings for electric cables and wires--Part 3:Identifications of cables and wires
GB 6995.4 Markings for electric cables and wires--Part 4:Identifications of insulated conductors of cables and wires for electrical appliances and equipments
GB 6995.5 Markings for electric cables and wires--Part 5:Identifications of insulated cores of power cables
GB/T 12706.2-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV)up to 35kV(Um=40.5kV) Part 2:Cables for rated voltages from 6kV(Um=7.2kV)up to 30kV(Um=36kV)
GB/T 1981.2 Varnishes used for electrical insulation.Part 2:Methods of test*, 2009-06-10 Update
GB/T 2951.1-1997 Common test methods for insulating and sheathing materials of electric cables. Part 1: Methods for general application. Section one: Measurement of thickness and overall dimensions--Tests for determining the mechanical properties
GB/T 2951.4-1997 Common test methods for insulating and sheating material of electric cables. Part 1: Methods for general application. Section four: Test at low temperature
GB/T 2951.5-1997 Common test methods for insulating and sheathing materials of electric cables. Part 2: Methods specific to elastomeric compounds. Section one: Ozone resistance test--Hot set test--Mineral oil immersion test
GB/T 2951.6-1997 Common test methods for insulating and sheathing materials of electric cables. Part 3: Methods specific to PVC compounds. Section one: Pressure test at high temperature--Test for resistance to cracking
GB/T 2951.7-1997 Common test methods for insulating and sheathing materials of electric cables. Part 3: Methods specific to PVC compounds. Section two: Loss of mass test--Thermal stability test
GB/T 3048.15-1992 Electric cables and wires--D.C.spark test method for insulated cores
GB/T 3048.4-1994 Test methods for determining electrical properties of electric cables and wires.Measurement of D.C. resistance of conductors
GB/T 3048.8-1994 Test methods for determining electrical properties of electric cables and wires.A.C. voltage tests
GB/T 3048.9 Test methods for electrical properties of electric cables and wires.Part 9: Spark test of insulated cores*, 2007-12-03 Update
JB/T 6213.2-2006 Flexiuie cables and cords for winding leads of electric motors Part 2: Flexible cables and cords with maximum continuous operating temperature of 70℃
JB/T 6213.3-2006 Flexiuie cables and cords for winding leads of electric motors Part 3: Flexible cables and cords with maximum continuous operating temperature of 90℃
JB/T 6213.4-2006 Flexiuie cables and cords for winding leads of electric motors Part 4: Flexible cables and cords with maximum continuous operating temperature of 180℃
JB/T 6213.5-2006 Flexiuie cables and cords for winding leads of electric motors Part 5: Freon resistant cords
JB/T 6213.1-2006 history
2006JB/T 6213.1-2006 Flexible cables and cords for winding leads of electric motors Part 1: General
1992JB/T 6213.1-1992 Flexible cables and cords for electrical machine winding connections - Part 1: General provisions