IEC TR2 61462:1998
Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations

Standard No.
IEC TR2 61462:1998
Release Date
1998
Published By
International Electrotechnical Commission (IEC)
Status
Latest
IEC TR2 61462:1998
Replace By
IEC 61462:2007
Scope
This technical report applies to composite hollow insulators consisting of a load bearing insulating tube made of resin impregnated fibres, a housing (outside the insulating tube) made of elastomeric material (for example silicone or ethylene-propylene) and metal fixing devices at the ends of the insulating tube. Composite hollow insulators as defined in this report are intended to be used under conditions involving internal pressure or free of pressure. They are intended for use in outdoor or indoor electrical equipment operating on alternating current with a rated voltage greater than 1 000 V and a frequency not greater than 100 Hz or for use in direct current equipment with a rated voltage greater than 1 500 V. The object of this report is: - to define the terms used; - to prescribe test methods; - to prescribe acceptance criteria. This report does not prescribe impulse voltage or power frequency voltage type tests or pollution tests because the withstand voltages are not characteristics of the hollow insulator itself, but of the apparatus of which it ultimately forms a part. NOTE 1 - "Internal pressure" means a permanent gas pressure greater than 0,05 MPa (0,5 bar) gauge. The gas can be dry air or inert gases, for example sulphur hexafluoride, nitrogen, or a mixture of such gases. NOTE 2 - "No internal pressure" means a gas or liquid pressure smaller than or equal to 0,05 MPa (0,5 bar) gauge. Where hydrostatic pressure exceeds 0,05 MPa different test procedures may be agreed. NOTE 3 - Composite hollow insulators are intended for use in electrical equipment, such as, but not limited to · circuit breakers; · switch-disconnectors; · disconnectors; · earthing switches; · instrument- and power transformers; · bushings. Additional testing defined by the relevant IEC equipment committee may be required.

IEC TR2 61462:1998 history

  • 1998 IEC TR2 61462:1998 Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations

IEC TR2 61462:1998 Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations was changed to IEC 61462:2007 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1000 V - Definitions, test methods, acceptance criteria and design recommendations.




Copyright ©2024 All Rights Reserved