UL 181B BULLETIN-2007
UL Standard for Safety Closure Systems for Use with Flexible Air Ducts and Air Connectors (COMMENTS DUE: October 01@ 2007)

Standard No.
UL 181B BULLETIN-2007
Release Date
2007
Published By
Underwriters Laboratories (UL)
Status
 2014-10
Replace By
UL 181B BULLETIN-2012
Latest
UL 181B-2021
Scope
These requirements cover pressure-sensitive tapes@ mastic systems@ and non-metallic mechanical fasteners for use as a part of the closure system of factory-made flexible air ducts or air connectors complying with the Standard for Factory-Made Air Ducts and Air Connectors@ UL 181. These requirements cover only pressure-sensitive tapes intended for use at the core to fitting attachment and at the outer moisture barrier. When used at the core to fitting attachment@ a mechanical fastener shall be installed over the tape. The tape shall be employed at this location such that it does not disrupt the connection of the mechanical fastener. When tape is used at the outer moisture barrier@ mechanical fasteners may or may not be employed. These requirements cover only mastic systems intended to be used with joints of factory-made flexible non-metallic air ducts or air connectors which employ mechanical fasteners (see 2.4). The joints@ without mastics@ shall comply with the requirements of the Standard for Factory-Made Air Ducts and Air Connectors@ UL 181. Mastic closure systems are intended for use as an additional seal at the attachment of the flexible non-metallic air duct cores (or air connectors). The mastic shall be installed uniformly around the mating surface of the fitting collar (i.e. sleeves@ elbows@ and the like) and in such a manner that it does not disrupt the connection of the mechanical fastener around the core. These requirements cover only non-metallic mechanical fasteners intended for use at the core to fitting attachment and at the outer moisture barrier of factory-made flexible non-metallic air ducts or air connectors. When these non-metallic fasteners are used@ beaded fittings are required@ and a maximum positive operating pressure shall be limited to 6 inch water column (1.5 kPa). Multiple lengths of fasteners may be joined to achieve longer length. Pressure-sensitive tapes@ mastic closure systems@ and non-metallic mechanical fasteners are intended for use with flexible air ducts and air connectors installed in accordance with the Standard for the Installation of Air Conditioning and Ventilating Systems@ NFPA 90A@ and the Standard for the Installation of Warm Air Heating and Air Conditioning Systems@ NFPA 90B; and/or Model codes.

UL 181B BULLETIN-2007 history

  • 1970 UL 181B-2021 Closure systems for use with flexible air ducts and air connectors
  • 2017 UL 181B BULLETIN-2017 UL Standard for Safety Closure Systems for Use with Flexible Air Ducts and Air Connectors (COMMENTS DUE: March 20@ 2017)
  • 2014 UL 181B BULLETIN-2014 UL Standard for Safety Closure Systems for Use with Flexible Air Ducts and Air Connectors (COMMENTS DUE: OCTOBER 30@ 2014)
  • 2013 UL 181B-2013 Closure systems for use with flexible air ducts and air connectors
  • 2012 UL 181B BULLETIN-2012 UL Standard for Safety Closure Systems for Use with Flexible Air Ducts and Air Connectors (COMMENTS DUE: October 08@ 2012)
  • 2007 UL 181B BULLETIN-2007 UL Standard for Safety Closure Systems for Use with Flexible Air Ducts and Air Connectors (COMMENTS DUE: October 01@ 2007)
  • 2005 UL 181B-2005 UL Standard for Safety Closure Systems for Use with Flexible Air Ducts and Air Connectors Second Edition; Reprint with revisions through and including February 13, 2008.
  • 2002 UL 181B BULLETINS-2002 11/22/2002 (18p) Comments Due:January 6,2003
  • 2002 UL 181B BULLETIN-2002 UL Standard for Safety Closure Systems for Use with Flexible Air Ducts and Air Connectors
  • 1995 UL 181B-1995 UL Standard for Safety Closure Systems for Use with Flexible Air Ducts and Air Connectors (First Edition)



Copyright ©2024 All Rights Reserved