Full Description 1.1 This practice outlines dosimetric procedures to be followed in irradiator characterization, process qualification, and routine processing of food with ionizing radiation from isotopic gamma sources to ensure that all product has been treated within a predetermined range of absorbed dose. Other procedures related to irradiator characterization, process qualification, and routine processing that may influence absorbed dose in the product are also discussed. Information about effective or regulatory dose limits for food products is not within the scope of this practice (see Guides F1355 and F1356). Note 1-Dosimetry is only one component of a total quality assurance program for adherence to good manufacturing practices used in the production of safe and wholesome food. Note 2-Practice E1431 describes dosimetric procedures for electron beam and bremsstrahlung (X-ray) irradiation facilities for food processing. 1.2 For guidance in the selection, calibration, and use of specific dosimeters, and interpretation of absorbed dose in the product from dosimetry measurements, see Guide E1261; Practices E666, E668, E1026, E1205, E1275, E1276, E1310, and E1401. For discussion of radiation dosimetry for gamma rays and X-rays see ICRU Report 14. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E1204-97e1 Referenced Document
ASTM E1026 Standard Practice for Using the Fricke Reference Standard Dosimetry System*, 1995-04-21 Update
ASTM E177 Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods*, 1990-04-21 Update
ASTM E275 Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers*, 1993-04-21 Update
ASTM E456 Standard Terminology for Relating to Quality and Statistics*, 1996-04-21 Update
ASTM E666 Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation*, 1997-04-21 Update
ASTM E668 Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices*, 2020-07-01 Update
ASTM E925 Standard Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Slit Width does not Exceed 2 nm*, 2002-03-10 Update
ASTM E958 Standard Practice for Measuring Practical Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers*, 1993-04-21 Update
ASTM F1355 Standard Guide for Irradiation of Fresh Fruits as a Phytosanitary Treatment*, 1999-04-21 Update
ASTM F1356 Standard Guide for the Irradiation of Fresh and Frozen Red Meat and Poultry to Control Pathogens and Other Microorganisms*, 1999-04-21 Update
ASTM F1736 Standard Guide for Irradiation of Finfish and Shellfish to Control Pathogens and Spoilage Microorganisms*, 1996-04-21 Update