Full Description 1.1 This practice covers the preparation, handling, testing, and procedure for using radiochromic liquid dosimetry systems of radiochromic dye solutions held in sealed or capped containers (for example, ampoules, vials) and the spectrophotometric or photometric readout equipment for measuring absorbed dose in materials irradiated by photons and electrons in terms of absorbed dose in water. 1.2 This practice applies to radiochromic liquid dosimeter solutions that can be used within part or all of the specified ranges as follows: 1.2.1 The absorbed dose range is from 0.5 to 40000 Gy for photons and electrons. 1.2.2 The absorbed dose rate is from 10 -3 to 1011 Gy/s. 1.2.3 The radiation energy range for photons is from 1 to 20 MeV. 1.2.4 The radiation energy range for electrons is from 0.01 to 20 MeV. Note 1-Since low-energy electrons, such as 0.01 MeV, may not penetrate the container of the solution, the solutions may be used in a stirred open beaker with the electrons entering the solutions directly (1). 1.2.5 The irradiation temperature range is from -40 to +60°C. 1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E1540-98e1 Referenced Document
ASTM C912 Standard Practice for Designing a Process for Cleaning Technical Glasses*, 1993-04-21 Update
ASTM E1026 Standard Practice for Using the Fricke Reference Standard Dosimetry System*, 1995-04-21 Update
ASTM E177 Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods*, 1990-04-21 Update
ASTM E178 Standard Practice for Dealing With Outlying Observations*, 1994-04-21 Update
ASTM E275 Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers*, 1993-04-21 Update
ASTM E456 Standard Terminology for Relating to Quality and Statistics*, 1996-04-21 Update
ASTM E666 Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation*, 1997-04-21 Update
ASTM E668 Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices*, 2020-07-01 Update
ASTM E925 Standard Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Slit Width does not Exceed 2 nm*, 2002-03-10 Update
ASTM E958 Standard Practice for Measuring Practical Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers*, 1993-04-21 Update