PD CEN/TS 16115-2:2016
Ambient air - Measurement of bioaerosols - Part 2: Planning and evaluation of plant-related plume measurements

Standard No.
PD CEN/TS 16115-2:2016
Release Date
2016
Published By
European Committee for Standardization (CEN)
Latest
PD CEN/TS 16115-2:2016
Replace
FprCEN/TS 16115-2-2016
Scope
This document describes the general requirements to be taken into account in planning and implementing plant-related plume measurements of microbial air pollutants. A basic principle of this method is to compare the concentrations in air unaffected by the activities of the plant (i.e. background air sampled upwind of the plant) with the concentration of bioaerosols in air downwind of the plant. It is this comparison that allows an assessment of the plant-related contribution and the mean spatial impact range to be made. As it has so far not been possible to set limit values based on dose-response relationships, the mean impact range is to be used as a first criterion for assessing the environmental impact of a plant. The scale of work for the plume measurements described is necessary to obtain statistically representative data about the impact range of the plant and/or source, taking into account the great variety of influencing factors. Plant-related measurements of bioaerosol concentrations in ambient air may be required in a number of regulatory situations. Examples of typical measurement objectives and indicative application scenarios are presented in the document. This method specifies the simultaneous measurement of background and downwind air quality to reduce the risk of invalid comparisons resulting from changing background air concentrations. Another important principle of this method is the requirement for repeated measures to take into account day to day and seasonal variations in the processes governing bioaerosol emissions and dispersion. The objective is to analyse a given measurement problem and derive the associated requirements for organization, the measurement method, the sampling strategy, the evaluation of the measured data, quality assurance and reporting.

PD CEN/TS 16115-2:2016 Referenced Document

  • EN 13098:2000 Workplace atmospheres - Guidelines for measurement of airborne micro-organisms and endotoxin
  • EN ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories (ISO/IEC 17025:2005)
  • VDI 4251 Blatt 1-2007 Measurement of airborne microorganisms and viruses in ambient air - Planning of plant-related ambient air measurements - Plume measurement

PD CEN/TS 16115-2:2016 history

  • 2016 PD CEN/TS 16115-2:2016 Ambient air - Measurement of bioaerosols - Part 2: Planning and evaluation of plant-related plume measurements
Ambient air - Measurement of bioaerosols - Part 2: Planning and evaluation of plant-related plume measurements



Copyright ©2024 All Rights Reserved