BS 8214:2016
Determination of fire resistance of doors 5 5 Marking 6 6 Specifying fire doors 7 7 Doors and frames 8 8 Handling and storage of doors on site 9 9 Installation of fire doors 10 10 Glazing 19 11 Door hardware

Standard No.
BS 8214:2016
Release Date
2016
Published By
British Standards Institution (BSI)
Latest
BS 8214:2016
Replace
BS 8214:2008

BS 8214:2016 Referenced Document

  • BS 476-31.1 Fire tests on building materials and structures — Part 31 : Methods for measuring smoke penetration through doorsets and shutter assemblies — Section 31.1 Method of measurement under ambient temperature conditions
  • BS 5499 Graphical symbols and signs - Safety signs, including fire safety signs - Creation and design of graphical symbols for use in safety signs - Requirements
  • BS 6262-4 Glazing for buildings. Code of practice for safety related to human impact*2018-05-30 Update
  • BS 7974 Application of fire safety engineering principles to the design of buildings. Code of practice*2019-03-31 Update
  • BS 8300 Design of buildings and their approaches to meet the needs of disabled people - Code of practice
  • BS 9991 Fire safety in the design, management and use of residential buildings – Code of practice
  • BS EN 1125 Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods
  • BS EN 1154 Building hardware — Controlled door closing devices — Requirements and test methods
  • BS EN 1155 Building hardware — Electrically powered hold - open devices for swing doors — Requirements and test methods
  • BS EN 1158 Building hardware — Door coordinator devices — Requirements and test methods
  • BS EN 12051 Building hardware - Door and window bolts - Requirements and test methods
  • BS EN 1303  Building hardware. Cylinders for locks. Requirements and test methods
  • BS EN 13637 Building hardware. Electrically controlled exit systems for use on escape routes. Requirements and test methods
  • BS EN 1366-4  Fire resistance tests for service installations. Linear joint seals*2021-08-25 Update
  • BS EN 1634-1 Safety and control devices for burners and appliances burning gaseous or liquid fuels. Combustion product sensing devices
  • BS EN 1634-3 Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Smoke control test for door and shutter assemblies
  • BS EN 179 Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods
  • BS EN 1935 Building hardware — Single - axis hinges — Requirements andtest methods
  • BS EN 942 Timber in joinery - General requirements

BS 8214:2016 history

  • 2016 BS 8214:2016 Determination of fire resistance of doors 5 5 Marking 6 6 Specifying fire doors 7 7 Doors and frames 8 8 Handling and storage of doors on site 9 9 Installation of fire doors 10 10 Glazing 19 11 Door hardware
  • 2008 BS 8214:2008 Code of practice for fire door assemblies
  • 1990 BS 8214:1990 Code of practice for fire door assemblies with non-metallic leaves
Determination of fire resistance of doors 5 5 Marking 6 6 Specifying fire doors 7 7 Doors and frames 8 8 Handling and storage of doors on site 9 9 Installation of fire doors 10 10 Glazing 19 11 Door hardware



Copyright ©2023 All Rights Reserved