Anhui Provincial Standard of the People's Republic of China
Latest
DB34/T 1431-2011
Scope
This standard specifies the product code and product representation method, cable model and specification of twist-resistant flexible cables for wind power generation with rated voltage 1.8/3 kV and below used in turbines and fixed installation towers in wind power equipment or other similar occasions. Technical requirements, test methods and inspection rules, packaging, transportation and storage. This standard applies to twist-resistant flexible cables for wind power generation with rated voltages 1.8/3 kV and below.
DB34/T 1431-2011 Referenced Document
GB/T 12706.1 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 1: Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)*, 2020-03-31 Update
GB/T 18380.11 Tests on electric and optical fibre cables under fire conditions—Part 11:Test for vertical flame propagation for a single insulated wire or cable—Apparatus*, 2022-03-09 Update
GB/T 18380.31 Tests on electric and optical fibre cables under fire conditions—Part 31: Test for vertical flame spread of vertically-mounted bunched wires or cables—Apparatus*, 2022-03-09 Update
GB/T 2423.17 Environmental testing for electric and electronic products.Part 2:Test method.Test Ka:Salt mist
GB/T 2951.12 Common test methods for insulating and sheathing materials of electric and optical cables.Part 12:Methods for general application.Thermal ageing methods
GB/T 2951.14 Common test methods for insulating and sheathing materials of electric and optical cables.Part 14:Methods for general application-Test at low temperature
GB/T 2951.21 Common test methods for insulating and sheathing materials of electric and optical cables.Part21:Methods specific to elastomeric compounds.Ozone resistance,hot set and mineral oil immersion tests
GB/T 2951.31 Common test methods for insulating and sheathing materials of electric and optical cables.Part31:Methods specific to PVC compounds.Pressure test at high temperature.Test for resistance to cracking
GB/T 3048.13 Test methods for electrical properties of electric cables and wires.Part 13: Impulse voltage test
GB/T 3048.4 Test methods for electrical properties of electric cables and wires.Part 4: Test of DC resistance of conductors
GB/T 3048.5 Test methods for electrical properties of electric cables and wires.Part 5: Test of insulation resistance
GB/T 3048.8 Test methods for electrical properties of electric cables and wires.Part 8: AC voltage test
GB/T 3048.9 Test methods for electrical properties of electric cables and wires.Part 9: Spark test of insulated cores
GB/T 4909.2 Test methods for bare wires.Part 2:Measurement of dimensions
GB/T 6995.1 Markings for electric wires and cables.Part: General requirements
GB/T 6995.4 Markings for electric wires and cables.Part 4:Identifications of insulated conductors of cables and wires for electrical appliances and equipments
JB/T 10696.7 Test methods for determining mechanical, physical and chemical properties of electric cables and wires Part 7: Tear test
DB34/T 1431-2011 history
2011DB34/T 1431-2011 Torsion-resistant flexible cable for wind power use with rated voltages up to and including 1.8/3 kV