VDI 6022 Blatt 5-2016
Ventilation and indoor-air quality - Avoidance of allergenic exposure - Requirements regarding the testing and evaluation of technical products and components affecting the indoor air

Standard No.
VDI 6022 Blatt 5-2016
Release Date
2016
Published By
Association of German Mechanical Engineers
Latest
VDI 6022 Blatt 5-2016
Replace
VDI 6022 Blatt 1-2011 VDI 6022 Blatt 5-2015
Scope
The standard provides a basis for the prevention of allergic potential of devices and products and makes it measurable. The standard describes existing instrumentation, testing and evaluation methods respecting the interest of consumers. It describes the methods of pollutant and allergen avoidance, largely protecting people from the contact and the inhalation of pollutants of various origins.The standard is particularly intended for use by trades whose activities have an impact on the quality of indoor air (architects and engineers, interior decorators, manufacturers of devices, components and products), testers and consumers concerned.

VDI 6022 Blatt 5-2016 Referenced Document

  • DIN 53122-1:2001 Testing of plastics and elastomer films, paper, board and other sheet materials - Determination of water vapour transmission - Part 1: Gravimetric method
  • DIN EN 1307:2016 Textile floor coverings - Classification; German version EN 1307:2014+A1:2016
  • DIN EN 13501-1:2010 Fire classification of construction products and building elements - Part 1: Classification using data from reaction to fire tests; German version EN 13501-1:2007+A1:2009
  • DIN EN 13725:2003 Air quality - Determination of odour concentration by dynamic olfactometry; German version EN 13725:2003
  • DIN EN 1822-1:2011 High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking; German version EN 1822-1:2009
  • DIN EN 1957:2013 Furniture.Beds and mattresses.Test methods for the determination of functional characteristics and assessment criteria; German version EN 1957:2012
  • DIN EN 60312:2008 Vacuum cleaners for household use - Methods of measuring the performance (IEC 60312:2007); German version EN 60312:2008
  • DIN EN 779:2012 Particulate air filters for general ventilation - Determination of the filtration performance; German version EN 779:2012
  • DIN EN 984:2002 Textile floor coverings - Determination of the mass per unit area of the use surface of needled floor coverings; German version EN 984:2001
  • DIN EN ISO 11092:2014 Textiles - Physiological effects - Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test) (ISO 11092:2014); German version EN ISO 11092:2014
  • DIN EN ISO 11378-2:2003 Textile floor coverings - Laboratory soiling tests - Part 2: Drum test (ISO 11378-2:2001); German version EN ISO 11378-2:2001
  • DIN EN ISO 3744:2011 Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane (ISO 3744:2010); German version EN ISO 3744:2010
  • DIN EN ISO 9237:1995 Textiles - Determination of permeability of fabrics to air (ISO 9237:1995); German version EN ISO 9237:1995

VDI 6022 Blatt 5-2016 history

  • 2016 VDI 6022 Blatt 5-2016 Ventilation and indoor-air quality - Avoidance of allergenic exposure - Requirements regarding the testing and evaluation of technical products and components affecting the indoor air
  • 2015 VDI 6022 BLATT 5-2015 Raumlufttechnik@ Raumluftqualitaet - Vermeidung allergener Belastungen - Anforderung an die Pruefung und Bewertung von technischen Geraeten und Komponenten mit Einfluss auf die Atemluft
  • 2011 VDI 6022 Blatt 1-2011 Ventilation and indoor-air quality - Hygiene requirements for ventilation and air-conditioning systems and units (VDI Ventilation Code of Practice)
  • 2007 VDI 6022 BLATT 2-2007 Hygiene-Anforderungen an Raumlufttechnische Anlagen und -Geraete - Messverfahren und Untersuchungen bei Hygienekontrollen und Hygieneinspektionen
  • 2006 VDI 6022 Blatt 1-2006 Hygiene-Anforderungen an Raumlufttechnische Anlagen und Geraete

VDI 6022 Blatt 5-2016 Ventilation and indoor-air quality - Avoidance of allergenic exposure - Requirements regarding the testing and evaluation of technical products and components affecting the indoor air has been changed from VDI 6022 Blatt 1-2011 Ventilation and indoor-air quality - Hygiene requirements for ventilation and air-conditioning systems and units (VDI Ventilation Code of Practice).

Ventilation and indoor-air quality - Avoidance of allergenic exposure - Requirements regarding the testing and evaluation of technical products and components affecting the indoor air