IEC/IEEE 62271-37-013:2015
High-voltage switchgear and controlgear - Part 37-013: Alternating-current generator circuit-breakers

Standard No.
IEC/IEEE 62271-37-013:2015
Release Date
2015
Published By
International Electrotechnical Commission (IEC)
Status
Replace By
IEC/IEEE 62271-37-013:2015/COR1:2017
Latest
IEC/IEEE 62271-37-013:2021
Replace
IEC 17A/1074/FDIS:2015
Scope
This part of IEC 62271 is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV. It is applicable to generator circuit-breakers that are installed between the generator and the transformer terminals. Requirements relative to generator circuit-breakers intended for use with generators and transformers rated 10 MVA or more are covered specifically. Generator circuits rated less than 10 MVA and pumped storage installations are considered special applications, and their requirements are not completely covered by this standard. This standard is also applicable to the operating mechanisms of generator circuit-breakers and to their auxiliary equipment.

IEC/IEEE 62271-37-013:2015 Referenced Document

  • IEC 60050-441:1984 International Electrotechnical Vocabulary. Part 441 : Chapter 441: Switchgear, controlgear and fuses
  • IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
  • IEC 60296:2012 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
  • IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF<(Index)6>) taken from electrical equipment and specification for its re-use
  • IEC 60529:1989 Degrees of protection provided by enclosures (IP code)
  • IEC 61180-1:1992 High-voltage test techniques for low-voltage equipment; part 1: definitions, test and procedure requirements
  • IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
  • IEC 62271-100:2008 High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
  • IEC 62271-1:2007 High-voltage switchgear and controlgear - Part 1: Common specifications
  • IEC/IEEE 62271-37-082:2012 High-voltage switchgear and controlgear - Part 37-082: Standard practice for the measurement of sound pressure levels on alternating current circuit-breakers

IEC/IEEE 62271-37-013:2015 history