BS 7629-1:2015
Electric cables, Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire. Multicore cables

Standard No.
BS 7629-1:2015
Release Date
2015
Published By
British Standards Institution (BSI)
Status
 2020-11
Replace By
BS 7629-1:2015+A1:2019
Latest
BS 7629-1:2015+A1:2019
Replace
BS 7629-1:2008

BS 7629-1:2015 Referenced Document

  • BS 5266-1  Emergency lighting. Code of practice for the emergency lighting of premises*2016-05-31 Update
  • BS 7655-1.2 Specification for insulating and sheathing materials for cables - Cross-linked elastomeric insulating compounds - General 90 °C application
  • BS 7655-6.1 
  • BS 7671 Requirements for Electrical Installations. IET Wiring Regulations*2022-03-28 Update
  • BS 8434-2 Methods of test for assessment of the fire integrity of electric cables - Part 2:Test for unprotected small cables for use in emergency circuits - BS EN 50200 with a 930 ° flame and with water spray
  • BS EN 50200  Method of test for resistance to fire of unprotected small cables for use in emergency circuits*2015-12-31 Update
  • BS EN 50363-1 Insulating, sheathing and covering materials for low voltage energy cables - Cross-linked elastomeric insulating compounds
  • BS EN 50363-5 Insulating, sheathing and covering materials for low voltage energy cables. Halogen-free, cross-linked insulating compounds
  • BS EN 50395 Electrical test methods for low voltage energy cables
  • BS EN 50396 Non electrical test methods for low voltage energy cables
  • BS EN 60228 
  • BS EN 60754-1 Test on gases evolved during combustion of materials from cables - Determination of the halogen acid gas content*2020-04-30 Update
  • BS EN 61034-1 Measurement of smoke density of cables burning under defined conditions. Test apparatus
  • BS EN 61034-2 Measurement of smoke density of cables burning under defined conditions - Test procedure and requirements*2020-03-31 Update
  • BS EN 62230 Electric cables. Spark-test method

BS 7629-1:2015 history

  • 2020 BS 7629-1:2015+A1:2019 Electric cables. Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire. Multicore cables
  • 2015 BS 7629-1:2015 Electric cables, Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire. Multicore cables
  • 2008 BS 7629-1:2008 Electric cables – Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire – Part 1: Multicore and multipair cables
  • 1997 BS 7629-1:1997 Specification for 300/500 V fire resistant electric cables having low emission of smoke and corrosive gases when affected by fire - Multicore cables



Copyright ©2023 All Rights Reserved