DIN EN ISO 52017-1:2018 Energy performance of buildings - Sensible and latent heat loads and internal temperatures - Part 1: Generic calculation procedures (ISO 52017-1:2017); German version EN ISO 52017-1:2017
This document specifies the general assumptions, boundary conditions and equations for the calculation, under transient hourly or subhourly conditions, of the internal temperatures (air and operative) and/or the heating, cooling and humidification and dehumidification loads to hold a specific (temperature, moisture) set point, in a single building zone. No specific numerical techniques are imposed by this document. Specific calculation procedures based on the generic calculation procedures of this document are given in ISO 52016-1. The specific simplifications, assumptions and boundary conditions in ISO 52016-1 are tailored to the respective application areas, such as the energy need for heating and cooling and for humidification and dehumidification, hourly internal temperature, design heating and cooling and humidification and dehumidification load.
DIN EN ISO 52017-1:2018 Referenced Document
DIN EN ISO 13370:2018 Thermal performance of buildings - Heat transfer via the ground - Calculation methods (ISO 13370:2017); German version EN ISO 13370:2017
DIN EN ISO 52000-1:2018-03 Energy performance of buildings - Overarching EPB assessment - Part 1: General framework and procedures (ISO 52000-1:2017)
DIN EN ISO 52010-1:2018 Energy performance of buildings - External climatic conditions - Part 1: Conversion of climatic data for energy calculations (ISO 52010-1:2017)
DIN EN ISO 7345:1996 Thermal insulation - Physical quantities and definitions (ISO 7345:1987); German version EN ISO 7345:1995
EN 15255:2007 Energy performance of buildings - Sensible room cooling load calculation - General criteria and validation procedures
EN 15265:2007 Energy performance of buildings - Calculation of energy needs for space heating and cooling using dynamic methods - General criteria and validation procedures
EN ISO 13791:2012 Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - General criteria and validation procedures
ISO 13370:2017 Thermal performance of buildings - Heat transfer via the ground - Calculation methods
ISO 13791:2012 Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - General criteria and validation procedures
ISO 13792:2012 Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - Simplified methods
ISO 52000-1:2017 Energy performance of buildings - Overarching EPB assessment - Part 1: General framework and procedures
ISO 52010-1:2017 Energy performance of buildings - External climatic conditions - Part 1: Conversion of climatic data for energy calculations
ISO 52016-1:2017 Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 1: Calculation procedures
ISO 7345:1987 Thermal insulation; Physical quantities and definitions
ISO/TR 52000-2:2017 Energy performance of buildings - Overarching EPB assessment - Part 2: Explanation and justification of ISO 52000-1
ISO/TR 52016-2:2017 Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
DIN EN ISO 52017-1:2018 history
2018DIN EN ISO 52017-1:2018-04 Energy performance of buildings - Sensible and latent heat loads and internal temperatures - Part 1: Generic calculation procedures (ISO 52017-1:2017); German version EN ISO 52017-1:2017
2018DIN EN ISO 52017-1:2018 Energy performance of buildings - Sensible and latent heat loads and internal temperatures - Part 1: Generic calculation procedures (ISO 52017-1:2017); German version EN ISO 52017-1:2017
1970DIN EN ISO 52017-1 E:2015-03 Building energy performance sensible and latent heat loads and indoor temperatures Part 1: General calculation procedure (draft)
2015DIN EN ISO 52017-1 E:2015 Draft Document - Energy performance of buildings - Calculation of the dynamic thermal balance in a building or building zone - Part 1: Generic calculation procedure (ISO/DIS 52017-1:2014); German version prEN ISO 52017-1:2014
2012DIN EN ISO 13792:2012 Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - Simplified methods (ISO 13792:2012); German version EN ISO 13792:2012
0000 DIN EN ISO 13792:2010
2007DIN EN 15265:2007 Energy performance of buildings - Calculation of energy needs for space heating and cooling using dynamic methods - General criteria and validation procedures; English version of DIN EN 15265:2007-11
2005DIN EN ISO 13792:2005 Thermal behavior of buildings – Calculation of summer room temperatures in buildings without system technology – Simplified calculation procedure
DIN EN ISO 52017-1:2018 Energy performance of buildings - Sensible and latent heat loads and internal temperatures - Part 1: Generic calculation procedures (ISO 52017-1:2017); German version EN ISO 52017-1:2017 has been changed from DIN EN 15255:2007 Energy performance of buildings - Sensible room cooling load calculation - General criteria and validation procedures; English version of DIN EN 15255:2007-11.
DIN EN ISO 52017-1:2018 Energy performance of buildings - Sensible and latent heat loads and internal temperatures - Part 1: Generic calculation procedures (ISO 52017-1:2017); German version EN ISO 52017-1:2017 has been changed from DIN EN 15265:2007 Energy performance of buildings - Calculation of energy needs for space heating and cooling using dynamic methods - General criteria and validation procedures; English version of DIN EN 15265:2007-11.
DIN EN ISO 52017-1:2018 Energy performance of buildings - Sensible and latent heat loads and internal temperatures - Part 1: Generic calculation procedures (ISO 52017-1:2017); German version EN ISO 52017-1:2017 has been changed from DIN EN ISO 13791:2012 Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - General criteria and validation procedures (ISO 13791:2012); German version EN ISO 13791:2012.
DIN EN ISO 52017-1:2018 Energy performance of buildings - Sensible and latent heat loads and internal temperatures - Part 1: Generic calculation procedures (ISO 52017-1:2017); German version EN ISO 52017-1:2017 has been changed from DIN EN ISO 13792:2012 Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - Simplified methods (ISO 13792:2012); German version EN ISO 13792:2012.