Scope
This European Standard specifies requirements, test methods and performance criteria for line detectors using an optical beam that detect smoke by utilizing the attenuation and/or changes in attenuation of an optical beam, for use in fire detection and fire alarm systems installed in buildings (see EN 54-1:2011). This European Standard provides for the assessment and verification of constancy of performance (AVCP) of line detectors using an optical beam to this EN. This European Standard does not cover:- line detectors using an optical beam designed to operate with separations between opposed components of less than 1 m; - line detectors using an optical beam whose optical path length is defined or adjusted by an integral mechanical connection; - line detectors using an optical beam with special characteristics, which cannot be assessed by the test methods in this European Standard. NOTE The term "optical" is used to describe that part of the electromagnetic spectrum produced by the transmitter to which the receiver is responsive; this is not restricted to visible wavelengths.

EN 54-12:2015 Referenced Document

  • EN 50130-4:2011 Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems (Incorporates Amendment A1: 2014)
  • EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
  • EN 54-7:2000 Fire detection and fire alarm systems - Part 7: Smoke detectors - Point detectors using scattered light, transmitted light or ionization (Incorporates Amendments A1: 2002 and A2: 2006)*2024-04-20 Update
  • EN 60064:1995 Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements (Incorporates Amendments A11: 2007 and A5: 2009)
  • EN 60068-1:2014 Environmental testing - Part 1: General and guidance
  • EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
  • EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
  • EN 60068-2-42:2003 Environmental testing Part 2-42: Tests Test Kc: Sulphur dioxide test for contacts and connections
  • EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
  • EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
  • EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
  • EN 60081:1998 Double-capped fluorescent lamps - Performance specifications (Incorporates Amendment A5: 2013)
  • EN ISO 9001:2008 Quality management systems - Requirements*2024-04-20 Update

EN 54-12:2015 history

  • 2015 EN 54-12:2015 Fire detection and fire alarm systems - Part 12: Smoke detectors - Line detectors using an optical beam
  • 2002 EN 54-12:2002 Fire detection and fire alarm systems - Part 12: Smoke detectors - Line detectors using an optical light beam