ISO 26367-2:2017
Guidelines for assessing the adverse environmental impact of fire effluents - Part 2: Methodology for compiling data on environmentally significant emissions from fires

Standard No.
ISO 26367-2:2017
Release Date
2017
Published By
International Organization for Standardization (ISO)
Latest
ISO 26367-2:2017
Scope
This document specifies a methodology for compiling the information needed to assess the environmental damage caused by a fire incident. This includes conducting a site reconnaissance, establishing data quality objectives and designing sampling programmes. This document also provides a standardized method for reporting the results of the compilation and findings of the analyses, for use in contingency planning or for the assessment of the potential adverse environmental impact of a specific fire incident. This document does not include specific instruction on sampling and analysis of fire effluents. Sampling and analysis are the focus of a future document in the ISO 26367 series. This document is applicable to uncontrolled fires, including fires in commercial and domestic premises, unenclosed commercial sites, agricultural storage sites, wildland and forest fires, as well as fires involving road, rail and maritime transport systems. This document focuses on the fire effluents that are environmentally significant, including pollutants causing short-term effects (e.g. pollutants causing biotope damage and components of smog) and long-term effects (e.g. persistent organic pollutants, POP). Since it is not possible to treat all potential pollutants that could be found in fire effluents in a single document, a list of those pollutants specifically addressed in this document is given below: a) pollutants with short-term effects: halogenated acids (HX), metals, nitrogen oxides (NOx), particulates, and sulfur oxides ISOx); b) pollutants with long-term effects: metals, particulates, perfluorinated compounds (PFC), polyaromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB), and polyhalogenated dioxins and furans (PXDD/PXDF). The reporting template provided in Annex D proposes additional potential pollutants and indicators for inclusion in the compilation. Not all of the pollutants and indicators listed in Table D.1 are relevant to every fire site, and others not mentioned in the table can apply. This document does not include direct acute toxicity issues on humans, which are covered by other standards, such as ISO 13344 and ISO 13571.  1 

ISO 26367-2:2017 Referenced Document

  • ASTM D5792-10 Standard Practice for Generation of Environmental Data Related to Waste Management Activities: Development of Data Quality Objectives*2024-04-20 Update
  • ASTM D6233-98 Standard Guide for Data Assessment for Environmental Waste Management Activities
  • ASTM E1527-13 Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process*2024-04-20 Update
  • ASTM E1903-11 Standard Guide for Environmental Site Assessments: Phase II Environmental Site Assessment Process*2024-04-20 Update
  • ASTM E2247-16 Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process for Forestland or Rural Property
  • ISO 5667-10:1992 Water quality; sampling; part 10: guidance on sampling of waste waters
  • ISO 5667-11:2009 Water quality - Sampling - Part 11: Guidance on sampling of groundwaters
  • ISO 5667-12:1995 Water quality - Sampling - Part 12: Guidance on sampling of bottom sediments
  • ISO 5667-13:2011 Water quality - Sampling - Part 13: Guidance on sampling of sludges
  • ISO 5667-14:2014 Water quality - Sampling - Part 14: Guidance on quality assurance and quality control of environmental water sampling and handling
  • ISO 5667-15:2009 Water quality - Sampling - Part 15: Guidance on the preservation and handling of sludge and sediment samples
  • ISO 5667-16:2017 Water quality - Sampling - Part 16: Guidance on biotesting of samples
  • ISO 5667-17:2008 Water quality - Sampling - Part 17: Guidance on sampling of bulk suspended solids
  • ISO 5667-19:2004 Water quality - Sampling - Part 19: Guidance on sampling in marine sediments
  • ISO 5667-1:2006 Water quality - Sampling - Part 1: Guidance on the design of sampling programmes and sampling techniques
  • ISO 5667-20:2008 Water quality - Sampling - Part 20: Guidance on the use of sampling data for decision making - Compliance with thresholds and classification systems
  • ISO 5667-21:2010 Water quality - Sampling - Part 21: Guidance on sampling of drinking water distributed by tankers or means other than distribution pipes
  • ISO 5667-22:2010 Water quality - Sampling - Part 22: Guidance on the design and installation of groundwater monitoring points
  • ISO 5667-23:2011 Water quality - Sampling - Part 23: Guidance on passive sampling in surface waters
  • ISO 5667-3:2012 Water quality - Sampling - Part 3: Preservation and handling of water samples
  • ISO 5667-4:2016 Water quality - Sampling - Part 4: Guidance on sampling from lakes, natural and man-made
  • ISO 5667-5:2006 Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
  • ISO 5667-6:2014 Water quality - Sampling - Part 6: Guidance on sampling of rivers and streams
  • ISO 5667-7:1993 Water quality; sampling; part 7: guidance on sampling of water and steam in boiler plants
  • ISO 5667-8:1993 Water quality; sampling; part 8: guidance on the sampling of wet deposition
  • ISO 5667-9:1992 Water quality; sampling; part 9: guidance on sampling from marine waters
  • ISO/IEC GUIDE 98-1:2009 Uncertainty of measurement — Part 1: Introduction to the expression of uncertainty in measurement*2024-04-20 Update
  • ISO/IEC GUIDE 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

ISO 26367-2:2017 history

  • 2017 ISO 26367-2:2017 Guidelines for assessing the adverse environmental impact of fire effluents - Part 2: Methodology for compiling data on environmentally significant emissions from fires
Guidelines for assessing the adverse environmental impact of fire effluents - Part 2: Methodology for compiling data on environmentally significant emissions from fires



Copyright ©2024 All Rights Reserved