IEC 62321-4:2017
Determination of certain substances in electrotechnical products - Part 4: Mercury in polymers, metals and electronics by CV-AAS, CV-AFS, ICP-OES and ICP-MS

Standard No.
IEC 62321-4:2017
Release Date
2017
Published By
International Electrotechnical Commission (IEC)
Status
 2017-07
Replace By
IEC 62321-4:2013/AMD1:2017
Latest
IEC 62321-4:2013/AMD1:2017
Scope
This part of IEC 62321 describes test methods for mercury in polymers, metals and electronics by CV-AAS, CV-AFS, ICP-OES and ICP-MS. This standard specifies the determination of the levels of mercury (Hg) contained in electrotechnical products. These materials are polymers, metals and electronics (e. g. printed wiring boards, cold cathode fluorescent lamps, mercury switches). Batteries containing Hg should be handled as described in [1]1. The interlaboratory study has only evaluated these test methods for plastics, other matrices were not covered. This standard refers to the sample as the object to be processed and measured. What the sample is or how to get to the sample is defined by the entity carrying out the tests. Further guidance on obtaining representative samples from finished electronic products to be tested for levels of regulated substances may be found in IEC 62321-2. It is noted that the selection and/or determination of the sample may affect the interpretation of the test results. This standard describes the use of four methods, namely CV-AAS (cold vapour atomic absorption spectrometry), CV-AFS (cold vapour atomic fluorescence spectrometry) ICP-OES (inductively coupled plasma optical emission spectrometry), and ICP-MS (inductively coupled plasma mass spectrometry) as well as several procedures for preparing the sample solution from which the most appropriate method of analysis can be selected by experts. Analysis by CV-AAS, CV-AFS, ICP-OES and ICP-MS allows the determination of the target element, mercury, with high precision (uncertainty in the low per cent range) and/or high sensitivity (down to the μg/kg level). The test procedures described in this standard are intended to provide the highest level of accuracy and precision for concentrations of mercury in the range from 4 mg/kg to 1000 mg/kg. The procedures are not limited for higher concentrations. For direct analysis, using thermal decomposition-gold amalgamation in conjunction with CV-AAS (TD(G

IEC 62321-4:2017 Referenced Document

  • IEC 62321-1:2013 Determination of certain substances in electrotechnical products .Part 1: Introduction and overview
  • IEC 62321-2:2013 Determination of certain substances in electrotechnical products - Part 2: Disassembly, disjointment and mechanical sample preparation
  • IEC 62321-3-1:2013 Determination of certain substances in electrotechnical products - Part 3-1: Screening test methods - Screening of electrotechnical products for lead, mercury, cadmium, total chromium and total bromine using X-ray fluorescence spectrometry
  • IEC 62554:2011 Sample preparation for measurement of mercury level in fluorescent lamps
  • ISO 3696:1987 Water for analytical laboratory use; Specification and test methods

IEC 62321-4:2017 history

  • 2017 IEC 62321-4:2013/AMD1:2017 Determination of certain substances in electrotechnical products - Part 4: Mercury in polymers, metals and electronics by CV-AAS, CV-AFS, ICP-OES and ICP-MS; Amendment 1
  • 2017 IEC 62321-4:2017 Determination of certain substances in electrotechnical products - Part 4: Mercury in polymers, metals and electronics by CV-AAS, CV-AFS, ICP-OES and ICP-MS