Scope

4.1 Radiation Shielding Window Components: 

4.1.1 Radiation shielding window components operability and long-term integrity are concerns that originate during the design and fabrication sequences. Such concerns can only be addressed, or are most efficiently addressed, during one or the other of these stages. The operability and integrity can be compromised during handling and installation sequences. For this reason, the subject equipment should be handled and installed under closely controlled and supervised conditions.

4.1.2 This standard is intended as a supplement to other standards and to federal and state regulations, codes, and criteria applicable to the design of radiation shielding window components.

1.1 Intent: 

1.1.1 The intent of this standard is to provide guidance for the design, fabrication, quality assurance, inspection, testing, packaging, shipping, installation, and maintenance of radiation shielding window components. These window components include wall liner embedments, dry lead glass radiation shielding window assemblies, oil-filled lead glass radiation shielding window assemblies, shielding wall plugs, barrier shields, view ports, and the installation/extraction table/device required for the installation and removal of the window components.

1.2 Applicability: 

1.2.1 This standard is intended for those persons who are tasked with the planning, design, procurement, fabrication, installation, and operation of the radiation shielding window components that may be used in the operation of hot cells, high level caves, mini-cells, canyon facilities, and very high level radiation areas.

1.2.2 This standard applies to radiation shielding window assemblies used in normal concrete walls, high-density concrete walls, steel walls and lead walls.

1.2.3 The values stated in SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. Common nomenclature for specifying some terms; specifically shielding, uses a combination of metric units and inch-pound units.

1.2.4 This standard identifies the special information required by the Manufacturer for the design of window components. Table A1.1 shows a sample list of the radiation source spectra and geometry information, typically required for shielding analysis. Table A2.1 shows a detailed sample list of specific data typically required to determine the physical size, glass types, and viewing characteristics of the shielding window, or view port. Annex A3 shows general window configuration sketches. Blank copies of

ASTM C1572/C1572M-17 Referenced Document

  • ANSI/ASME NQA-1 Quality Assurance Requirements for Nuclear Facility Applications
  • ANSI/AWS A2.4 Standard Symbols for Welding@ Brazing@ and Nondestructive Examination (7th Edition)
  • ANSI/AWS B2.1 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding with Consumable Inserts followed by Shielded Metal Arc Welding of Austenitic Stainless Steel (M-8/P-8/S-8, Group 1), 1/8 through 1-1/2 inch Thick, IN3XX, ER3XXX, and E3XX-XX, As-W
  • ANSI/ISO/ASQ 9001 Quality management systems - Requirements
  • ASTM A240/A240M Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications
  • ASTM A27/A27M Standard Specification for Steel Castings, Carbon, for General Application
  • ASTM A36/A36M Standard Specification for Carbon Structural Steel
  • ASTM A48/A48M Standard Specification for Gray Iron Castings
  • ASTM A747/A747M Standard Specification for Steel Castings, Stainless, Precipitation Hardening
  • ASTM C1533 Standard Guide for General Design Considerations for Hot Cell Equipment
  • ASTM C1661 Standard Guide for Viewing Systems for Remotely Operated Facilities
  • ASTM C859 Standard Terminology Relating to Nuclear Materials
  • ASTM D1533 Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration*2024-04-20 Update
  • ASTM E165 Standard Test Method for Liquid Penetrant Examination
  • ASTM E170 Standard Terminology Relating to Radiation Measurements and Dosimetry
  • ASTM E2024 Standard Test Methods for Atmospheric Leaks Using a Thermal Conductivity Leak Detector

ASTM C1572/C1572M-17 history

  • 2023 ASTM C1572/C1572M-23 Standard Guide for Dry Lead Glass and Oil-Filled Lead Glass Radiation Shielding Window Components for Remotely Operated Facilities
  • 2018 ASTM C1572/C1572M-18 Standard Guide for Dry Lead Glass and Oil-Filled Lead Glass Radiation Shielding Window Components for Remotely Operated Facilities
  • 2017 ASTM C1572/C1572M-17 Standard Guide for Dry Lead Glass and Oil-Filled Lead Glass Radiation Shielding Window Components for Remotely Operated Facilities
  • 2010 ASTM C1572-10 Standard Guide for Dry Lead Glass and Oil-Filled Lead Glass Radiation Shielding Window Components for Remotely Operated Facilities
  • 2004 ASTM C1572-04 Standard Guide for Dry Lead Glass and Oil-Filled Lead Glass Radiation Shielding Window Components for Remotely Operated Facilities
Standard Guide for  Dry Lead Glass and Oil-Filled Lead Glass Radiation Shielding  Window Components for Remotely Operated Facilities



Copyright ©2024 All Rights Reserved