ISO 10077-2:2017
Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames

Standard No.
ISO 10077-2:2017
Release Date
2017
Published By
International Organization for Standardization (ISO)
Latest
ISO 10077-2:2017
Scope
This document specifies a method and gives reference input data for the calculation of the thermal transmittance of frame profiles and of the linear thermal transmittance of their junction with glazing or opaque panels. The method can also be used to evaluate the thermal resistance of shutter profiles and the thermal characteristics of roller shutter boxes and similar components (e.g. blinds). This document also gives criteria for the validation of numerical methods used for the calculation. This document does not include effects of solar radiation, heat transfer caused by air leakage or threedimensional heat transfer such as pinpoint metallic connections. Thermal bridge effects between the frame and the building structure are not included. NOTE Table 1 in the Introduction shows the relative position of this document within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.

ISO 10077-2:2017 Referenced Document

  • EN 12412-2:2003 Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 2: Frames
  • EN 12519:2004 Windows and pedestrian doors - Terminology
  • EN 12664:2001 Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Dry and moist products of medium and low thermal resistance
  • EN 13556:2003 Round and sawn timber - Nomenclature of timbers used in Europe
  • EN 673:2011 Glass in building - Determination of thermal transmittance (U value) - Calculation method
  • ISO 10077-1:2006 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General
  • ISO 10211:2007 Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculations
  • ISO 10292:1994 Glass in building - Calculation of steady-state U values (thermal transmittance) of multiple glazing
  • ISO 10456:2007 Building materials and products - Hygrothermal properties - Tabulated design values and procedures for determining declared and design thermal values
  • ISO 12567-2:2005 Thermal performance of windows and doors - Determination of thermal transmittance by hot box method - Part 2: Roof windows and other projecting windows
  • ISO 12631:2012 Thermal performance of curtain walling - Calculation of thermal transmittance
  • ISO 15099:2003 Thermal performance of windows, doors and shading devices - Detailed calculations
  • ISO 52000-1:2017 Energy performance of buildings - Overarching EPB assessment - Part 1: General framework and procedures
  • ISO 6946:2007 Building components and building elements - Thermal resistance and thermal transmittance - Calculation method
  • ISO 7345:1987 Thermal insulation; Physical quantities and definitions
  • ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
  • ISO/TR 52000-2:2017 Energy performance of buildings - Overarching EPB assessment - Part 2: Explanation and justification of ISO 52000-1
  • ISO/TR 52022-2:2017 Energy performance of buildings - Thermal, solar and daylight properties of building components and elements - Part 2: Explanation and justification

ISO 10077-2:2017 history

  • 2017 ISO 10077-2:2017 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames
  • 2012 ISO 10077-2:2012/cor 1:2012 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames; Technical Corrigendum 1
  • 2012 ISO 10077-2:2012 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames
  • 2003 ISO 10077-2:2003 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames
Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames