IEC 61291-5-2:2017
Optical amplifiers - Part 5-2: Qualification specifications - Reliability qualification for optical fibre amplifiers

Standard No.
IEC 61291-5-2:2017
Release Date
2017
Published By
International Electrotechnical Commission (IEC)
Status
Replace By
IEC 61291-5-2:2017/COR1:2019
Latest
IEC 61291-5-2:2017/COR1:2019
Replace
IEC 86C/1376/CDV:2016 IEC 61291-5-2:2002
Scope
This part of IEC 61291 applies to optical amplifiers (OAs) and optically amplified, elementary sub-systems for terrestrial applications, using active fibres (optical fibre amplifiers (OFAs)) containing rare-earth dopants, which are commercially available. The black box approach is used in this document. The black box approach is adopted in order to give product specifications which are independent of OA implementation details. For reliability qualification purposes, some information about the internal components is needed; these internal parts are themselves treated as black boxes. This document gives requirements for the evaluation of OA reliability by combining the reliability of such internal black boxes. The object of this document is to specify the minimum list of reliability qualification tests, requirements on failure criteria during testing and on reliability predictions, and give the relevant normative references to establish a standard method for the assessment of the reliability of OFA devices and sub-systems in order to minimize risks and to promote product development and reliability qualification.

IEC 61291-5-2:2017 Referenced Document

  • IEC 60050-731:1991 International electrotechnical vocabulary; chapter 731: optical fibre communication
  • IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
  • IEC 60068-2-21:2006 Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
  • IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
  • IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
  • IEC 60068-2-31:2008 Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
  • IEC 60068-2-78:2012 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
  • IEC 61291-1:2012 Optical amplifiers - Part 1: Generic specification
  • IEC 61300-2-4:1995 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention
  • IEC 62005-9-1:2015 Fibre optic interconnecting devices and passive components - Reliability - Part 9-1: Qualification of passive optical components
  • IEC 62005-9-2:2007 Reliability of fibre optic interconnecting devices and passive optical components - Part 9-2: Reliability qualification for single fibre optic connector sets - Single mode

IEC 61291-5-2:2017 history

  • 2019 IEC 61291-5-2:2017/COR1:2019 Corrigendum 1 - Optical amplifiers - Part 5-2: Qualification specifications - Reliability qualification for optical fibre amplifiers
  • 2017 IEC 61291-5-2:2017 Optical amplifiers - Part 5-2: Qualification specifications - Reliability qualification for optical fibre amplifiers
  • 2002 IEC 61291-5-2:2002 Optical amplifiers - Part 5-2: Qualification specifications; Reliability qualification for optical fibre amplifiers
Optical amplifiers - Part 5-2: Qualification specifications - Reliability qualification for optical fibre amplifiers



Copyright ©2024 All Rights Reserved