IEC 60238:2016
Edison screw lampholders

Standard No.
IEC 60238:2016
Release Date
2016
Published By
International Electrotechnical Commission (IEC)
Status
Replace By
IEC 60238:2017
Latest
IEC 60238:2016/AMD2:2020
Replace
IEC 34B/1852/FDIS:2016 IEC 60238:2004 IEC 60238 AMD 1:2008 IEC 60238 AMD 2:2011 IEC 60238 Edition 8.1:2008 IEC 60238 Edition 8.2:2011
Scope
This International Standard applies to lampholders with Edison thread E14@ E27 and E40@ designed for connection to the supply of lamps and semi-luminaires1 only. It also applies to switched-lampholders for use in AC circuits only@ where the working voltage does not exceed 250 V r.m.s. This standard also applies to lampholders with Edison thread E5 designed for connection to the supply mains of series connected lamps@ with a working voltage not exceeding 25 V@ to be used indoors@ and to lampholders with Edison thread E10 designed for connection to the supply mains of series connected lamps@ with a working voltage not exceeding 60 V@ to be used indoors or outdoors. It also applies to lampholders E10 for building-in@ for the connection of single lamps to the supply. These lampholders are not intended for retail sale. As far as it reasonably applies@ this standard also covers lampholders other than lampholders with Edison thread designed for connection of series-connected lamps to the supply. NOTE This type of lampholder is for example used in Christmas tree lighting chains. As far as it reasonably applies@ this standard also covers adapters. This standard also covers lampholders which are@ wholly or partly@ integral with a luminaire or intended to be built into appliances. It covers the requirements for the lampholder only. For all other requirements@ such as protection against electric shock in the area of the terminals or of the lamp cap@ the requirements of the relevant appliance standard are observed and tested after building into the appropriate equipment@ when that equipment is tested according to its own standard. Such lampholders as well as lampholders provided with a snap-on outer shell@ for use by luminaire manufacturers only@ are not for retail sale. This standard applies to lampholders to be used indoors or outdoors in residential as well as in industrial lighting installations. It also applies to candle lampholders. In locations where special conditions prevail@ as for street lighting@ on board ships@ in vehicles and in hazardous locations@ for example where explosions are liable to occur@ special constructions may be required. This standard does not apply to three-light lampholders E26d. This standard is based on the following data relative to lamps for general lighting service: ?C caps E14 are used for lamps with a current not exceeding 2 A; ?C caps E27 are used for lamps with a current not exceeding 4 A; ?C caps E40 are used for lamps with a current not exceeding 16 A@ or 32 A if the nominal voltage of the supply does not exceed 130 V (see 5.5 and 6.3). Where lampholders are used in luminaires@ their maximum operating temperatures are specified in IEC 60598. 1 Requirements for lampholders suitable for semi-luminaires are under consideration.

IEC 60238:2016 Referenced Document

  • IEC 60061-1:1969 Lamp caps and holders together with gauges for the control of interchangeability and safety. Part 1 : Lamp caps
  • IEC 60061-2:1969 Lamp caps and holders together with gauges for the control of interchangeability and safety. Part 2 : Lampholders
  • IEC 60061-3:1969 Lamp caps and holders together with gauges for the control of interchangeability and safety. Part 3 : Gauges
  • IEC 60061-DB:2005 Lamp caps and holders together with gauges for the control of interchangeability and safety - 12-month subscription to online database comprising all parts of IEC 60061
  • IEC 60068-2-32:1975 Basic environmental testing procedures. Part 2 : Tests. Test Ed: Free fall
  • IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
  • IEC 60112:2003 Method for the determination of the proof and the comparative tracking indices of solid insulating materials
  • IEC 60227-1:2007 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements
  • IEC 60227-2:1997 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 2: Test methods
  • IEC 60227-3:1993 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V; part 3: non-sheathed cables for fixed wiring
  • IEC 60227-4:1992 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V; part 4: sheathed cables for fixed wiring
  • IEC 60227-5:2011 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)
  • IEC 60227-6:2001 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 6: Lift cables and cables for flexible connections
  • IEC 60227-7:1995 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Flexible cables screened and unscreened with two or more conductors

IEC 60238:2016 history




Copyright ©2024 All Rights Reserved