This International Standard applies to lampholders with Edison thread E14, E27 and E40,
designed for connection to the supply of lamps and semi-luminaires* only.
It also applies to switched-lampholders for use in a.c. circuits only, where the working voltage
does not exceed 250 V r.m.s.
This standard also applies to lampholders with Edison thread E5 designed for connection to the
supply mains of series connected lamps, with a working voltage not exceeding 25 V, to be used
indoors, and to lampholders with Edison thread El0 designed for connection to the supply
mains of series connected lamps, with a working voltage not exceeding 60 V, to be used
indoors or outdoors. It also applies to lampholders El0 for building-in, for the connection of
single lamps to the supply. These lampholders are not intended for retail sale.
As far as it reasonably applies, this standard also covers lampholders other than lampholders
with Edison thread designed for connection of series-connected lamps to the supply.
NOTE This type of lampholder is for example used in Christmas tree lighting chains.
As far as it reasonably applies, this standard also covers adapters.
This standard also covers lampholders which are, wholly or partly, integral with a luminaire or
intended to be built into appliances. It covers the requirements for the lampholder only. For all
other requirements, such as protection against electric shock in the area of the terminals or of
the lamp cap, the requirements of the relevant appliance standard shall be observed and
tested after building into the appropriate equipment, when that equipment is tested according to
its own standard. Such lampholders as well as lampholders provided with a snap-on outer
shell, for use by luminaire manufacturers only, are not for retail sale.
This standard applies to lampholders to be used indoors or outdoors in residential as well as in
industrial lighting installations. It also applies to candle lampholders. In locations where special
conditions prevail, as for street lighting, on board ships, in vehicles and in hazardous locations,
e.g. where explosions are liable to occur, special constructions may be required.
NOTE 1 This standard does not apply to three-light lampholders E26d.
NOTE 2 This standard is based on the following data relative to lamps for general lighting service:
- caps E14 are used for lamps with a current not exceeding 2 A;
- caps E27 are used for lamps with a current not exceeding 4 A;
- caps E40 are used for lamps with a current not exceeding 16 A.
NOTE 3 If the nominal voltage of the supply does not exceed 130 V, the maximum current for caps E4O is 32 A
(see 4.5 and 5.3).
NOTE 4 Where lampholders are used in luminaires, their maximum operating temperatures are specified in
IEC 60598.
IEC 60529:1989 Degrees of protection provided by enclosures (IP code)
IEC 60598 Luminaires Part 2: Particular Requirements Section 9: Photo and Film Luminaires (Non-Professional) (Edition 2.0; Includes Amendment 1: 06-1993)
IEC 60598-1 Interpretation Sheet 1 — Luminaires — Part 1: General requirements and tests*, 2023-08-31 Update