EN 14812:2005+A1:2007
Water conditioning equipment inside buildings - Chemical dosing systems - Pre-set dosing systems - Requirements for performance, safety and testing

Standard No.
EN 14812:2005+A1:2007
Release Date
2007
Published By
European Committee for Standardization (CEN)
Latest
EN 14812:2005+A1:2007
Replace
EN 14812-2005 EN 14812/prA1-2006
Scope
This European Standard specifies definitions, principles of construction (but not dimensions) and design, requirements on performance and operation as well as methods for testing the performance of chemical preset dosing systems for conditioning water intended for human consumption inside buildings (see [8]) which are permanently connected to the mains supply.

EN 14812:2005+A1:2007 Referenced Document

  • EN 1267:1999 Valves - Test of Flow Resistance Using Water as Test Fluid
  • EN 55011:2007 Industrial@ scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement (Incorporates Amendments A2: 2007; Remains Current)
  • EN 60204-1:2006 Safety of machinery - Electrical equipment of machines Part 1: General requirements (Incorporates Amendment A1: 2009; Incorporating corrigendum February 2010)
  • EN 60335-1:2002 Household and similar electrical appliances ?Safety Part 1: General requirements Incorporates Amendments A2: 2006, A11: 2004 and A12: 2006; Incorporating corrigendum January 2007; Incorporates Amendment A13: 2008; Incorporating corrigendum July 2009 and*2024-04-20 Update
  • EN 60335-2-41:2003 Household and similar electrical appliances - Safety Part 2-41: Particular requirements for pumps (Incorporates Amendment A2: 2010)
  • EN 60730-2-8:2002 Automatic electrical controls for household and similar use Part 2-8: Particular requirements for electrically operated water valves, including mechanical requirements (Incorporates Amendment A1: 2003)
  • EN 806-2:2005 Specification for installations inside buildings conveying water for human consumption - Part 2: Design
  • EN ISO 10304-1:1995 Water Quality - Determination of Dissolved Fluoride, Chloride, Nitrite, Orthophosphate, Bromide, Nitrate and Sulfate Ions, Using Liquid Chromatography of Ions - Part 1: Method for Water with Low Contamination (ISO 10304-1 : 1992)
  • EN ISO 10304-2:1996 Water Quality - Determination of Dissolved Anions by Liquid Chromatography of Ions - Part 2: Determination of Bromide, Chloride, Nitrate, Nitrite, Orthophosphate and Sulfate in Waste Water ISO 10304-2: 1995
  • EN ISO 10304-3:1997 Water Quality - Determination of Dissolved Anions by Liquid Chromatography of Ions - Part 3: Determination of Chromate, Iodide, Sulfite, Thiocyanate and Thiosulfate ISO 10304-3: 1997
  • EN ISO 10304-4:1999 Water Quality - Determination of Dissolved Anions by Liquid Chromatography of Ions - Part 4: Determination of Chlorate, Chloride and Chlorite in Water with Low Contamination ISO 10304-4: 1997

EN 14812:2005+A1:2007 history

  • 2007 EN 14812:2005+A1:2007 Water conditioning equipment inside buildings - Chemical dosing systems - Pre-set dosing systems - Requirements for performance, safety and testing
  • 2005 EN 14812:2005 Water conditioning equipment inside buildings - Chemical dosing systems - Pre-set dosing systems - Requirements for performance, safety and testing (Incorporates Amendment A1: 2007)