The design rules hereafter apply to flat ends and plates and tube bundles of heat exchangers as far as their staying effect is concerned. They are based on the Kirchhoff equations for plates taking into consideration the effect of the boundary conditions and multiple openings approximately. In addition, the C-factors also include the effect of a Poisson's ratio of 0,3.