5.1 This test method for the spectrometric analysis of metals and alloys is primarily intended to test such materials for compliance with compositional specifications. It is assumed that all who use this test method will be analysts capable of performing common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory.
1.1 This test method covers the simultaneous determination of 21 alloying and residual elements in carbon and low-alloy steels by spark atomic emission vacuum spectrometry in the mass fraction ranges shown Note 1.
Element | Composition Range, % | |
Applicable Range, | Quantitative Range, | |
Aluminum | 0 to 0.093 | 0.006 to 0.093 |
Antimony | 0 to 0.027 | 0.006 to 0.027 |
Arsenic | 0 to 0.1 | 0.003 to 0.1 |
Boron | 0 to 0.007 | 0.0004 to 0.007 |
Calcium | 0 to 0.003 | 0.002 to 0.003 |