Note 2: The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.
6.1 The assumptions of the physical system are given as follows:
6.1.1 The aquifer is of uniform thickness and confined by impermeable beds above and below.
6.1.2 The aquifer is of constant homogeneous porosity and matrix compressibility and of homogeneous and isotropic hydraulic conductivity.
6.1.3 The origin of the cylindrical coordinate system is taken to be on the well-bore axis at the top of the aquifer.
6.1.4 The aquifer is fully screened.
6.2 The assumptions made in defining the momentum balance are as follows:
6.2.1 The average water velocity in the well is approximately constant over the well-bore section.
6.2.2 Flow is laminar and frictional head losses from flow across the well screen are negligible.
6.2.3 Flow through the well screen is uniformly distributed over the entire aquifer thickness.
6.2.4 Change in momentum from the water velocity changing from radial flow through the screen to vertical flow in the well are negligible.
6.2.5 The system response is an exponentially decaying sinusoidal function.
1.1 This test method covers determination of transmissivity from the measurement of the damped oscillation about the equilibrium water level of a well-aquifer system to a sudden change of water level in a well. Underdamped response of water level in a well to a sudden change in water level is characterized by oscillatory fluctuation about the static water level with a decrease in the magnitude of fluctuation and recovery to initial water level. Underdamped response may occur in wells tapping highly transmissive confined aquifers and in deep wells having long water columns.
1.2 This analytical procedure is used in conjunction with the field procedure Test Method D4044 for collection of test data.