EN 54-29:2015 Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors
This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in buildings (see EN 54-1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor. The overall fire detection performance is determined utilizing the combination of the detected phenomena. This European Standard provides for the assessment and verification of constancy of performance (AVCP) of point detectors using a combination of smoke and heat sensors to this European Standard. Point detectors using a combination of smoke and heat sensors having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this European Standard (e. g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method). NOTE Certain types of detector contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not specified in this European Standard.
EN 54-29:2015 Referenced Document
EN 50130-4:2011 Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems (Incorporates Amendment A1: 2014)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
EN 54-2:1997 Fire detection and fire alarm systems - Part 2: Control and indicating equipment (Incorporates Amendment A1: 2006)
EN 54-5:2000 Fire Detection and Fire Alarm Systems - Part 5: Heat Detectors - Point Detectors*, 2024-04-20 Update
EN 54-7:2000 Fire detection and fire alarm systems - Part 7: Smoke detectors - Point detectors using scattered light, transmitted light or ionization (Incorporates Amendments A1: 2002 and A2: 2006)*, 2024-04-20 Update
EN 60068-1:1994 Environmental Testing Part 1: General and Guidance (Remains Current)
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60068-2-30:2005 Environmental Testing - Part 2: Tests - Test Db and Guidance: Damp Heat, Cyclic (12 + 12 Hour Cycle)*, 2024-04-20 Update
EN 60068-2-42:2003 Environmental testing Part 2-42: Tests Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
EN 60068-2-75:1997 Environmental Testing Part 2: Tests - Test Eh: Hammer Tests (Remains Current)
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ISO 209:2007 Aluminium and aluminium alloys - Chemical composition
EN 54-29:2015 history
2017EN 54-29:2015/PRA1:2017 Fire detection and fire alarm systems - Part 29: Multisensor fire detectors - Point detectors using a combination of smoke and heat sensors
2015EN 54-29:2015 Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors