IEC 61010-2-010:2014
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-010: Particular requirements for laboratory equipment for the heating of materials

Standard No.
IEC 61010-2-010:2014
Release Date
2014
Published By
International Electrotechnical Commission (IEC)
Status
Replace By
IEC 61010-2-010:2019 RLV
Latest
IEC 61010-2-010:2019 RLV
Scope
Equipment included in scope This part of IEC 61010 specifies general safety requirements for the following types of electrical equipment and their accessories@ wherever they are intended to be used. a) Electrical test and measurement equipment This is equipment which by electromagnetic means tests@ measures@ indicates or records one or more electrical or physical quantities@ also non-measuring equipment such as signal generators@ measurement standards@ power supplies for laboratory use@ transducers@ transmitters@ etc. NOTE 1 This includes bench-top power supplies intended to aid a testing or measuring operation on another piece of equipment. Power supplies intended to power equipment are within the scope of IEC 61558 (see 1.1.2 h)). This standard also applies to test equipment integrated into manufacturing processes and intended for testing manufactured devices. NOTE 2 Manufacturing test equipment is likely to be installed adjacent to and interconnected with industrial machinery in this application. b) Electrical industrial process-control equipment This is equipment which controls one or more output quantities to specific values@ with each value determined by manual setting@ by local or remote programming@ or by one or more input variables. c) Electrical laboratory equipment This is equipment which measures@ indicates@ monitors@ inspects or analyses materials@ or is used to prepare materials@ and includes in vitro diagnostic (IVD) equipment. This equipment may also be used in areas other than laboratories; examples include selftest IVD equipment to be used in the home and inspection equipment to be used to check people or material during transportation. Equipment excluded from scope This standard does not apply to equipment within the scope of: a) IEC 60065 (Audio@ video and similar electronic apparatus); b) IEC 60204 (Safety of machinery ?C Electrical equipment of machines); c) IEC 60335 (Household and similar electrical appliances); d) IEC 60364 (Electrical installations of buildings); e) IEC 60439 (Low-voltage switchgear and controlgear assemblies); f) IEC 60601 (Medical electrical equipment); g) IEC 60950 (Information technology equipment including electrical business equipment@ except as specified in 1.1.3); h) IEC 61558 (Power transformers@ power supply units and similar); i) IEC 61010-031 (Hand-held probe assemblies); j) IEC 61243-3 (Live working ?C Voltage detectors ?C Part 3: Two-pole low-voltage type). Computing equipment This standard applies only to computers@ processors@ etc. which form part of equipment within the scope of this standard or are designed for use exclusively with the equipment. NOTE Computing devices and similar equipment within the scope of IEC 60950 and conforming to its requirements are considered to be suitable for use with equipment within the scope of this standard. However@ some of the requirements of IEC 60950 for resistance to moisture and liquids are less stringent than those in this standard (see 5.4.4 second paragraph)). Scope and object Equipment included in scope Replacement: This part of IEC 61010 specifies safety requirements for electrically powered laboratory equipment for the heating of materials@ where the heating of materials is one of the functions of the equipment. NOTE If all or part of the equipment falls within the scope of one or more other part 2 standards of IEC 61010 as well as within the scope of this standard@ it will also need to meet the requirements of those other part 2 standards. In particular@ if equipmen is intended to be used for IVD purposes@ it will need to meet the requirements of IEC 61010-2-101. Equipment excluded from scope Addition after item j): aa) equipment for the heating and ventilation of laboratories; bb) sterilizing equipment; cc) heating and/or cooling equipment which the OPERATOR is intended to enter@ and which is large enough for the OPERATOR to remain inside with the door or doors closed.

IEC 61010-2-010:2014 history

  • 0000 IEC 61010-2-010:2019 RLV
  • 2014 IEC 61010-2-010:2014 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-010: Particular requirements for laboratory equipment for the heating of materials
  • 2005 IEC 61010-2-010:2005 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-010: Particular requirements for laboratory equipment for the heating of materials
  • 2003 IEC 61010-2-010:2003 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-010: Particular requirements for laboratory equipment for the heating of materials
  • 1970 IEC 61010-2-010:1992/AMD1:1996 Amendment 1 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-010: Particular requirements for laboratory equipment for the heating of material
  • 1992 IEC 61010-2-010:1992 Safety requirements for electrical equipment for measurement, control, and laboratory use; part 2-010: particular requirements for laboratory equipment for the heating of materials