ASTM D6513-14
Standard Practice for Calculating the Superimposed Load on Wood-frame Walls for Standard Fire-Resistance Tests

Standard No.
ASTM D6513-14
Release Date
2014
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D6513-21
Latest
ASTM D6513-21
Scope

4.1 Test Methods E119 and E1529, and other standard fire resistance test methods specify that throughout exposures to fire and the hose stream, a constant superimposed axial load be applied to a load-bearing test specimen to simulate a maximum load condition. They specify that this superimposed load shall be as nearly as practicable the maximum load allowed by design under nationally recognized structural design criteria. For this practice, the nationally recognized structural design criteria is the National Design Specification for Wood Construction (NDS).

4.1.1 Alternatively, the standard fire resistance test methods shall be conducted by applying an axial load that is less than the maximum allowable axial load as addressed by the NDS and this practice, but these tests shall be identified in the test report as being conducted under restricted load conditions. The superimposed axial load, as well as the superimposed axial load as a percentage of the maximum allowable axial design load as addressed by the NDS and this practice shall be included in the test report.

4.2 This practice describes procedures for calculating the superimposed axial load to be applied in standard fire resistance tests of wood-frame wall assemblies.

4.3 Statements in either the fire resistance test method standard or the nationally recognized structural design standard supercede any procedures described by this practice.

4.4 The NDS shall be consulted to ensure calculations are in compliance with all applicable provisions of that document.

1.1 This practice covers procedures for calculating the superimposed axial load required to be applied to load-bearing wood-frame walls throughout standard fire-resistance and fire and hose-stream tests.

1.2 The calculations determine the maximum load allowed by design for wood-frame wall assemblies under nationally recognized structural design criteria.

1.3 This practice is only applicable to those wood-frame assemblies for which the nationally recognized structural design criteria is the National Design Specification for Wood Construction (NDS).2

1.4 The system of units to be used is that of the nationally recognized structural design criteria. For the NDS, the units are inch-pound.

1.5 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use......

ASTM D6513-14 Referenced Document

  • ASTM D9 Standard Terminology Relating to Wood
  • ASTM E119 Standard Test Methods for Fire Tests of Building Construction and Materials
  • ASTM E1529 Standard Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies
  • ASTM E176 Standard Terminology of Fire Standards

ASTM D6513-14 history

  • 2021 ASTM D6513-21 Standard Practice for Calculating the Superimposed Load on Wood-frame Walls for Standard Fire-Resistance Tests
  • 2014 ASTM D6513-14 Standard Practice for Calculating the Superimposed Load on Wood-frame Walls for Standard Fire-Resistance Tests
  • 2008 ASTM D6513-08 Standard Practice for Calculating the Superimposed Load on Wood-frame Walls for Standard Fire-Resistance Tests
  • 2000 ASTM D6513-00(2005) Standard Practice for Calculating the Superimposed Load on Wood-frame Walls for Standard Fire-Endurance Tests
  • 2000 ASTM D6513-00 Standard Practice for Calculating the Superimposed Load on Wood-frame Walls for Standard Fire-Endurance Tests
Standard Practice for  Calculating the Superimposed Load on Wood-frame Walls for Standard  Fire-Resistance Tests



Copyright ©2024 All Rights Reserved