ASTM E844-09(2014)e1
Standard Guide for Sensor Set Design and Irradiation for Reactor Surveillance, E 706 (IIC)

Standard No.
ASTM E844-09(2014)e1
Release Date
2009
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM E844-09(2014)e2
Latest
ASTM E844-18
Scope

4.1 In neutron dosimetry, a fission or non-fission dosimeter, or combination of dosimeters, can be used for determining a fluence rate, fluence, or neutron spectrum in nuclear reactors. Each dosimeter is sensitive to a specific energy range, and, if desired, increased accuracy in a fluence-rate spectrum can be achieved by the use of several dosimeters each covering specific neutron energy ranges.

4.2 A wide variety of detector materials is used for various purposes. Many of these substances overlap in the energy of the neutrons which they will detect, but many different materials are used for a variety of reasons. These reasons include available analysis equipment, different cross sections for different fluence-rate levels and spectra, preferred chemical or physical properties, and, in the case of radiometric dosimeters, varying requirements for different half-life isotopes, possible interfering activities, and chemical separation requirements.

1.1 This guide covers the selection, design, irradiation, post-irradiation handling, and quality control of neutron dosimeters (sensors), thermal neutron shields, and capsules for reactor surveillance neutron dosimetry.

1.2 The values stated in SI units are to be regarded as standard. Values in parentheses are for information only.

1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E844-09(2014)e1 history

  • 2018 ASTM E844-18 Standard Guide for Sensor Set Design and Irradiation for Reactor Surveillance
  • 2014 ASTM E844-09(2014)e2 Standard Guide for Sensor Set Design and Irradiation for Reactor Surveillance
  • 2009 ASTM E844-09(2014)e1 Standard Guide for Sensor Set Design and Irradiation for Reactor Surveillance, E 706 (IIC)
  • 2009 ASTM E844-09 Standard Guide for Sensor Set Design and Irradiation for Reactor Surveillance, E 706(IIC)
  • 2003 ASTM E844-03 Standard Guide for Sensor Set Design and Irradiation for Reactor Surveillance, E 706(IIC)
  • 1997 ASTM E844-97 Standard Guide for Sensor Set Design and Irradiation for Reactor Surveillance, E 706(IIC)



Copyright ©2024 All Rights Reserved