IEC 60099-9:2014
Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations

Standard No.
IEC 60099-9:2014
Release Date
2014
Published By
International Electrotechnical Commission (IEC)
Latest
IEC 60099-9:2014
Replace
IEC 37/417/FDIS:2014
Scope
This part of IEC 60099 applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal@ multiterminal and back-to-back type up to and including an operating voltage of 1 100 kV. The standard applies in general to porcelain-housed and polymer-housed type arresters but also to gas-insulated metal enclosed arresters (GIS-arresters) solely used as d.c. bus and d.c. line/cable arresters. Arresters for voltage source converters are not covered. Arresters applied on the a.c. systems at the converter station and subjected to power-frequency voltage of 50 or 60 Hz principally without harmonics are tested as per IEC 60099-4. The arresters on a.c.-filters are tested according to this standard.

IEC 60099-9:2014 Referenced Document

  • CISPR 16-1-1-2010 Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques – Partie 1-1: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélec
  • CISPR/TR 18-2-2010 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits
  • IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
  • IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
  • IEC 60068-2-11:1981 Basic environmental testing procedures. Part 2 : Tests. Test Ka: Salt mist
  • IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
  • IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2: Tests - Test Q: Sealing
  • IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
  • IEC 60099-4:2004 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
  • IEC 60143-2:2012 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
  • IEC 60270:2000 High-voltage test techniques - Partial discharge measurements
  • IEC 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation

IEC 60099-9:2014 history

  • 2014 IEC 60099-9:2014 Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations
Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations