IEC 62271-211:2014
High-voltage switchgear and controlgear - Part 211: Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV

Standard No.
IEC 62271-211:2014
Release Date
2014
Published By
International Organization for Standardization (ISO)
Status
 2015-08
Replace By
IEC 62271-211:2014/COR1:2015
Latest
IEC 62271-211:2014/COR2:2017
Replace
IEC 17C/596/FDIS:2014 IEC/TR2 61639:1996
Scope
"This part of IEC 62271 is applicable to single and three phase direct connections between gas-insulated metal-enclosed switchgear (GIS) for rated voltages above 52 kV and transformer arrangements to establish electrical and mechanical interchange ability and to determine the limits of supply of for the transformer connection. Direct connections are immersed on one end in the transformer oil or insulating gas and on the other end in the insulating gas of the switchgear. Transformer arrangements are single-phase transformers with single-phase enclosed arrangement@ three-phase transformers with three single-phase enclosed arrangements or three-phase transformers with a three-phase enclosed arrangement with three transformer bushings. The connection satisfies the requirements of IEC 62271-203 for gas-insulated metal-enclosed switchgear@ IEC 60076 for power transformer and IEC 60137 for completely immersed bushings. For the purpose of this international standard the term ""switchgear"" is used for ""gas-insulated metal-enclosed switchgear""."

IEC 62271-211:2014 Referenced Document

  • IEC 60076 Power transformers
  • IEC 60076-10-1:2005 Power transformers - Part 10-1: Determination of sound levels - Application guide
  • IEC 60076-10:2005 Power transformers - Part 10: Determination of sound levels
  • IEC 60076-11:2004 Power transformers - Part 11: Dry-type transformers
  • IEC 60076-12:2008 Power transformers - Part 12: Loading guide for dry-type power transformers
  • IEC 60076-13:2006 Power transformers - Part 13: Self-protected liquid-filled transformers
  • IEC 60076-14:2013 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
  • IEC 60076-1:2011 Power transformers - Part 1: General
  • IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
  • IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
  • IEC 60076-4:2002 Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing; Power transformers and reactors
  • IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
  • IEC 60076-6:2007 Power transformers - Part 6: Reactors
  • IEC 60076-7:2005 Power transformers - Part 7: Loading guide for oil-immersed power transformers
  • IEC 60076-8:1997 Power transformers - Application guide

IEC 62271-211:2014 history

  • 2017 IEC 62271-211:2014/COR2:2017 Corrigendum 2 - High-voltage switchgear and controlgear - Part 211: Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
  • 2015 IEC 62271-211:2014/COR1:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR – Part 211: Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV (Edition 1.0)
  • 2014 IEC 62271-211:2014 High-voltage switchgear and controlgear - Part 211: Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
High-voltage switchgear and controlgear - Part 211: Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV